48 Interpreter Parameters
LocalTalk Parameters 2
The RS-422 port supports LocalTalk. Table 2-13 lists the factory default settings
for %LocalTalk% and %LocalTalk_Pending%.
Table 2-13 Parameters for %LocalTalk% and %LocalTalk_Pending%
Key Type Default Description
DelayedOutputClose boolean false Determines how the output channel
is managed after a job completes
execution.
When the value of this parameter is
set to true, an end of file indicator
is not sent until all of the pages of a
job have been printed. The network
channel remains open. Messages
such as printer error messages are
sent to the channel if it is either
the output channel for the job
executing, or the output channel for
jobs that have finished executing
but have not finished printing.
Enabled boolean true Indicates whether data arriving at
the printer should be scheduled
for processing. If the value of
this parameter is true, data is
processed. If the value is false,
data is not processed.
Filtering name /None Controls whether or not the Adobe
IntelliSelect heuristics are used for
automatic protocol detection.
Supported values are /None, which
means that automatic protocol
handling does not occur, and
/InterpreterBased, which
means that the heuristics are used.
They are generally used when
Interpreter is set to
/AutoSelect.
HasNames boolean false Indicates whether the printer
supports named files. If the printer
is not mounted, or if Type is
/Communications, the value of
this parameter is false. This value
is a read-only constant.
continued