User`s guide

For modem operation,
SW1-7 should always be ON and
SW2-7 should always be OFF.
*For printer operation, the setting may vary.
If using an Imagewriter II
SW1-7 should be ON and
SW2-7 should be OFF.
SW2 Dip Switch Settings
Switches SW2-1 through SW2-4 functions depend upon whether modem or printer
operation is enabled.
SW2 Dip Switch 1-4 Settings for Modem operation
Data Parity Stop SW2-1 SW2-2 SW2-3 SW2-4
Bits Bits
7 none 1 on off off on
7 odd 1 on off on off
7 even 1 on off off off
7 none 2 off off off on
7 odd 2 off off on off
7 even 2 off off off off
8 none 1 on on off on
8 odd 1 on on on off
8 even 1 on on off off
8 none 2 off on off on
8 odd 2 off on on off
8 even 2 off on off off
SW2 Dip Switch 1-4 Settings for Printer operation
SW2-1 Default data format
on 8 data, 1 stop
off 8 data, 2 stop
SW2-2 Delay after sending out a RETURN character
off None
on 32 milliseconds
SW2-3 and SW2-4 set line width and video output
2-3 2-4 Function
on on 40 column output, video on
on off 72 column output, video off
off on 80 column output, video off
off off 132 column output, video off
SW2 Dip Switch 5-7 Settings (Modem or Printer operation)