Specifications
Take Apart Main Deflection Board - 49
review CRT safety in
Bulletins/Safety.
Caution:
Never use a
grounding wriststrap until
after discharging the CRT.
1 Disconnect two-wire
cable BP2 (black and
white wires) from the
main deflection board.
2 Disconnect the two yoke
connectors
• Red and blue wire at
BL1
• Yellow and brown
wire at BF1