Specifications
Troubleshooting Symptom Charts /Miscellaneous - 5
Miscellaneous
Power lamp not on;
machine dead
1 Plug in power cord.
2 Close lamp cover and turn button clockwise.
3 Check for correct setting of voltage selector (on
international models).
4 Check interlock switch with multimeter. Replace switch if it
is not opening and closing.
5 Check fuses FU1, FU2, and FU3 on power supply board.
6 Replace logic board.
7 Replace power supply.
8 Replace transformer.