User manual

95.08.23.09.16
Color LaserWriter 12/600 PS Take Apart 3–19
Fuser Oil Extraction
(page 4 of 5)
Extraction from the overflow pan:
An oil overflow condition is sensed when a float-type actuator in the
overflow pan breaks the photo-interrupter of sensor PS10. The oil that
is buoying the actuator can be extracted from the overflow pan though a
well located on the delivery side of the fuser assembly.
2 Elevate the gear end of the fuser assembly so that oil flows toward the
well. Remove the well cover and well cap.
Well Cap Well
Well Cover