User Guide
Using the AV760
CAUTION: Do not connect the AV760 to systems
under high pressure. While the AV760 is designed to
withstand accidental exposure to positive pressures,
continued exposure may cause permanent damage.
1. Using the Appion Swivel Vacuum Connector
(included), connect the AV760 to an available
service port furthest from the vacuum pump.
2. Hand-tighten the connections to ensure a tight
connection. Never tool-tighten a knurled tting.
3. Press the Power button to turn on the AV760. A
countdown will display while the AV760 starts up
and performs self testing.
4. Press and hold the Units button for 1 second to
cycle the displayed Units (optional).
Tip: Connect to the Side Access Port on a Vacuum-
Rated Valve Core Removal Tool with the Appion
Swivel Vacuum Connector. Make sure the core
depressor side is attached to the Valve Core Removal
Tool.
Tip: Make sure the AV760 is vertical, with the
fitting pointed downward. This will help minimize
contamination from any oil that may be pulled out of
the system during evacuation.