Installation Guide
Table Of Contents
AT-130 Installation Manual
600840-000064, rev 0.4 Page 5 of 5
4. Installing AT-130
Installation Location
Choose an installation location that meets the following specifications:
• Mounted on a clean, flat surface.
• Mounted as high up as possible.
• The top (recommended) or top side of the unit has a clear view of the sky (not
underneath or blocked by a metal surface).
• The device shall be installed so on the equipment so that the operator is, at minimum, 20
cm away from all external surfaces of the device.
Installing AT-130
Use 1/4" or M5 bolts, washers, and nuts to mount AT-130 to its mounting location. Torque to a
maximum of 15 ft-lbs.
The spacing between bolts is 114mm, as shown below.