Datasheet

APP
A 60 & 90 Series Multimeter
• Analog Bar Graph • True RMS • Auto Power Off • Beep Guard™
• Frequency Counter • Capacitance Ranges • Continuity/Diode Test
• Water Resistant • Drop Proof • Protective Holster
SPECIFICATIONS: (All at 23°C ± 5°C, 80% R.H.)
Specifications subject to change without notice. Copyright © 2002 APPA Tech., Corp. All rights reserved
Distrubuted by:
Advanced Instrument Technology Made Easy
APPA TECHNOLOGY CORPORATION
9F, 119-1 Pao-Zong Rd., Shintien, Taipei, 231, TAIWAN
Tel: +886-2-29178820 Fax: +886-2-29170848
E-mail: info@appatech.com · http://www.appatech.com
ISO 9001 CERTIFIED
APPA 60 & 90 SERIES MULTIMETER
FEATURES:
GENERAL:
Digital display 3200 count 3200 count 3200 count 2000 count 2000 count 3200 count
Analog bar graph 65 segments 65 segments 65 segments 65 segments
Range selection Auto/Manual Auto/Manual Auto/Manual Manual Manual Auto/Manual
Frequency counter
Capacitance measurement
Audible continuity and Diode test
Data hold
Delay hold
True RMS measuring APPA 97R
Beep guard
Automatic power shut off
Shock proof from 4 feet drops 5 feet 5 feet 5 feet
Standard full-sleeve safety test leads
Protective holster
Water resistant and dust proof case
APPA 63N APPA 67 APPA 69 APPA 91 APPA 93N APPA 97/97R
Sampling Rate: 2times/sec for digital display, 12times/sec for analog bar graph 2times/sec 2times/sec 2times/sec 2.5times/sec 2.5times/sec
Overload Indication "1" or "-1" "1" or "-1" "1" or "-1" "1" or "-1" "1" or "-1" "OL" or "-OL"
Low Battery Indication
Auto Power Off: Approx. 30 minutes
Operating Temperature: 0°C~50°C, 80% RH
Storage Temperature: - 20°C ~ 60°C
Temperature Coefficient: 0.15(Spec. Acc)/°C, <18°C or>28°C
Safety: IEC 61010 and designed to meet UL3111 specifications CAT. III 600V CAT. II 600V CAT. II 600V CAT. III 600V CAT. II 600V CAT.III600V
Power Requirement: Single 9V battery (NEDA 1604 or IEC 6F22)
IEC LR03, AM4 or AAA size 1.5V x 2
Battery Life: In hours (Alkaline battery) 1000 900 600 300 150 700/ 97R 350
Size: 80mm(W) x 165mm (L) x 36 mm(H), with holster
85mm(W) x 165mm (L) x 40 mm (H), with holster
84mm(W) x 175mm (L) x 31 mm(H), without holster
95mm(W) x 192mm (L) x 50 mm (H), with holster
Weight: In grams (with holster) 310 360 370 550 550 550
Included with instrument: Test Leads, Protective holster
ZnC battery (installed) and manual
DCV: Ranges 300.0mV~600V 300.0mV~600V 300.0mV~600V 200.0mV~1000V 200.0mV~600V 300.0mV~1000V
Resolution 0.1mV 0.1mV 0.1mV 0.1mV 0.1mV 0.1mV
Accuracy ±(0.5%+2d) ±(0.7%+2d) ±(0.5%+2d) ±(0.5%+1d) ±(0.5%+1d) ±(0.5%+2d)/ 97R ±(0.3%+2d)
Input Impedance:10M
Overload Protection: 600V DC or AC rms 1200V DC or 850V AC 1000V rms
ACV: Ranges 3.000V~600V 3.000V~600V 3.000V~600V 200.0mV~750V 200.0mV~600V 3.000V~750V
Resolution 1mV 1mV 1mV 0.1mV 0.1mV 1mV
Accuracy: ±(1.5%+5d) at 40Hz~500Hz ±(1.7%+5d)
at 40Hz~500Hz • ±(1.25%+4d) • ±(1.3%+4d) • ±(1.3%+5d)/ 97R ±( 1.3%+3d)
Input Impedance:10M//<100pF
Overload Protection: 600V DC or AC rms
1000V DC or AC peak 1200V DC or 850V AC
Conversion Type: Average sensing RMS indicating
DCA: Ranges: ( 20A for 30 seconds ) 300.0µA 300.0µA~20.00A 300.0µA~20.00A 200.0µA~20.00A 200.0µA~20.00A 300.0µA~20.00A
Resolution 0.1µA 0.1µA 0.1µA 0.1µA 0.1µA 0.1µA
Accuracy: ±(1.2%+2d) basic, ±(2.5%+5d) at >300mA ±(1.0%+2d )
±( 0.9%+2d) basic, ±(2.5%+5d) at >300mA
±(2%+3d) at >2A • ±(1%+1d) basic • ±(1%+1d) basic • ±(1%+2d) basic
Input Protection: 1A, 240V fuse for µA/mA input
13A, 240V fuse for A/10A input
600V rms
1A/500V and 16A/500V fast blow fuses
ACA: Ranges: ( 20A for 30 seconds ) 300.0µA~20.00A 300.0µA~20.00A 200.0µA~20.00A 200.0µA~20.00A 300.0µA~20.00A
Resolution 0.1µA 0.1µA 0.1µA 0.1µA 0.1µA
Accuracy: ±(1.7%+4d) basic, ±(2.9%+7d) >300mA
±(1.5%+4d) basic, ±(2.9%+5d) >300mA
±(1.5%+3d) basic • ±(2.5%+3d) at >2A • ±(2.5%+3d) at >2A • ±(2.5%+5d) at >2A
all at 40Hz ~ 500Hz
Input Protection: Same as DCA
OHM: Ranges 300.0~30.00M 300.0~30.00M 300.0~30.00M 200.0~20.00M 200.0~20.00M 300.0~30.00M
Resolution 0.1 0.1 0.1 0.1 0.1 0.1
Accuracy: 300 / 200 ±(1.0%+4d) ±(1.2%+4d) ±(1.0%+4d) ±(0.75%+4d) ±(0.8%+4d ±(1.0%+4d)/ 97R ±(0.7%+4d )
3K/ 2K ±(0.8%+2d) ±(0.9%+2d) ±(0.8%+2d) ±(0.75%+1d) ±(0.8%+1d) ±(0.8%+2d)/ 97R ±(0.5%+2d )
30K/ 20K ±(0.8%+2d) ±(0.9%+2d) ±(0.8%+2d) ±(0.75%+1d) ±(0.8%+1d) ±(0.8%+2d)/ 97R ±(0.5%+2d )
300K/ 200K ±(0.8%+2d) ±(0.9%+2d) ±(0.8%+2d) ±(0.75%+1d) ±(0.8%+1d) ±(0.8%+2d)/ 97R ±(0.5%+2d )
3M/ 2M ±(0.8%+2d) ±(1.2%+3d) ±(1.0%+3d) ±(0.75%+1d) ±(0.8%+1d) ±(1.2%+3d)/ 97R ±(1.0%+3d)
30M/ 20M ±(2.0%+5d) ±(2.5%+5d) ±(2.0%+5d) ±(1.5%+5d) ±(1.5%+5d) ±(2.5%+5d)/ 97R ±(2.0%+5d)
Overload Protection 600V rms 600V rms 600V rms 500V rms 600V rms 600V rms
Continuity Beeper: <50, 2KHz tone buzzer
Diode Test: Open circuit voltage: 3.3V max
Frequency Counter: Ranges 2KHz~200KHz
Resolution 1Hz
Accuracy: ±(1%+3d) at 5V rms max
Overload Protection 600Vrms
Capacitance: Ranges 3.000µF~3000µF 2.000nF~200.0µF
Resolution 1nF 1pF
Accuracy: ±(1.9%+5d) basic 2%+4d