Datasheet
APPA New 60 Series
Copyright © 2012 APPA Tech., Corp. All rights reserved
BATTERY EASY TO REPLACE
Unscrew only one screw to remove
battery door for battery replacement,
designed for user's convenience
without opening the bottom case.
NONE CONTACT VOLTAGE
DETECTING
APPA New 60 series have VoltSense™
feature to detect live cable and oultlet
without contact also find the cable
alignment behind the wall as cable finder.
ADD-VALUE DESIGN
Every 60 series meters are
designed with two sides soft
grips for better user-friendly
and convenience, also
include a built-in smart tilt
stand, a nail hook,
and convenient
test lead storage.
NEW SLIM DESIGN
Ergonomically designed slim shape
with one hand operated knob and
buttons. Just fit the palm of your
hand and your needs.
APPA 62T
2000 count large scale digital
display
Autoranging and manual
selection
ACV, DCV, Ohm, Continuity
and Diode function
0.5% basic DCV accuracy
Data Hold
VoltSense™ feature (None
contact voltage detecting)
10Amp ACA/DCA range
MAX/MIN function key
Frequency Counter
Capacitor measurement
Temperature measurement
Temp. adaptor and bead probe
included
Auto Power Off (Disable)
Shock proof from 4 feet drops
Probe holder and tilt stand
Soft grips of over molding
CAT. III 600V Safety standard
APPA 61
2000 count large scale digital
display
Autoranging and manual
selection
ACV, DCV, Ohm, Continuity
and Diode function
0.5% basic DCV accuracy
Data Hold
VoltSense™ feature (None
contactvoltage detecting)
Auto Power Off (Disable)
Shock proof from 4 feet drops
Probe holder and tilt stand
Soft grips of over molding
CAT. III 600V Safety standard
NEW
APPA 66R
APPA 66RT
(Temperature Function)
6000 count large scale digital
display
Auto detect AC/DC on Voltage
and Ampere
Autoranging and manual selection
ACV, DCV, Ohm, Continuity
and Diode function
True RMS reading on AC mode
0.5% basic DCV accuracy
Smart Data Hold
VoltSense™ feature (None contact
voltage detecting)
10Amp ACA/DCA range
PEAK Hold/Relative function key
Frequency measurement
Capacitor measurement
Temperature measurement (66RT only)
Auto Power Off (Disable)
Beep Guard
Shock proof from 4 feet drops
Comfortable Holster with Probe
holder and tilt stand
CAT. III 600V Safety standard
APPA 62
APPA 62R
(True-RMS reading)
2000 count large scale digital
display
Autoranging and manual
selection
ACV, DCV, Ohm, Continuity
and Diode function
True RMS reading on AC mode
(62R only)
0.5% basic DCV accuracy
Data Hold
VoltSense™ feature (None
contact voltage detecting)
10Amp ACA/DCA range
MAX/MIN function key
Frequency Counter
Capacitor measurement
Auto Power Off (Disable)
Shock proof from 4 feet drops
Probe holder and tilt stand
Soft grips of over molding
CAT. III 600V Safety standard
A
2
d
A
s
A
a
0
D
V
c
A
S
P
P
S
C
A
2
d
A
s
A
a
0
D
V
c
1
M
F
F
C
T
T
i
A
S
P
S
A
60
di
A
an
A
A
an
T
r
0
.
S
V
o
VV
vo
10
10
P
Fr
C
T
e
TT
A
B
S
Top of Low-Cost Digital Multimeters
APPA 61 APPA 62/62R APPA 62T APPA 66R/66RT
2000 count 2000 count 2000 count 6000 count
Auto/Manual Auto/Manual Auto/Manual Auto/Manual
N/A (62R onl y) N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
APPA NEW 60 SERIES MULTIMETERS
FEATURES:
Digital display
True RMS measuring
Auditable continuity and Diode test
Beep guard
hff
Peak hold/Relative mode
Data hold
MIN/MAX function
VoltSense TM
Frequency counter
Capacitance measurement
Range selection
Automatic power shut off
Shock proof from 4 feet drops
Standard full-sleeve safety teat leads
DCV Ranges 200.0mV ~ 1000V 200.0mV ~ 1000V 200.0mV ~ 1000V 60mV ~ 1000V
Resolution 0.01mV 0.01mV 0.01mV 0.01mV
Basic Accuracy ±(0.5%+2d) ±(0.5%+2d) ±(0.5%+2d) ±(0.5%+2d)
Input Impedance: 10MΩ
Overload Protection: 1000VDC
ACV Ranges 200.0mV ~ 750V 200.0mV ~ 750V 200.0mV ~ 750V 60mV ~ 1000V
Resolution 1mV 1mV 1mV 0.01mV
Basic Accuracy: At 50Hz ~ 60Hz ±(1.5%+5d) ±(1.5%+5d) ±(1.5%+5d) ±(1.0%+5d)
Input Impedance: 10MΩ
Overload Protection
750VDC 750VDC 750VDC 1000VDC
Conversion Type: Average sensing RMS indicating
True RMS (62R only) True RMS
DCA Ranges 2.000A/10.00A 2.000A/10.00A 6.000A/10.00A
SPECIFICATIONS: (All at 23ƍ ±5ƍ, Ŝ80% R.H.)
Resolution
1mA
1mA
1mA
Basic Accuracy ±(1.0%+3d) ±(1.0%+3d) ±(1.0%+2d)
Input Protection:10A/500V fast blowfuse for A input
ACA Ranges 2.000A/10.00A 2.000A/10.00A 6.000A/10.00A
Resolution 1mA 1mA 1mA
Basic Accuracy: At 50Hz ~ 60Hz ±(1.5%+5d) ±(1.5%+5d) ±(1.5%+5d)
Input Protection: 10A/500V fast blowfuse for A input
Conversion Type: Average sensing RMS indicating
True RMS (62R only) True RMS
OHM Ranges 200.0Ω ~ 20.00MΩ 200.0Ω ~ 20.00MΩ 200.0Ω ~ 20.00MΩ 600.0Ω ~ 40.00MΩ
Resolution 0.1Ω 0.1Ω 0.1Ω 0.01Ω
Basic Accuracy ±(1.0%+3d) ±(1.0%+3d) ±(1.0%+3d) ±(0.8%+2d)
Overload Protection: 600V rms
Continuity Beeper 2kHz tone Buzzer
<150Ω <150Ω <150Ω <30Ω
Diode Test Max. Open Circuit Voltage 2V 2V 2V 1.8V
N/A
N/A
Frequency Counter
Ranges
2kHz ~ 20MHz
2kHz ~ 20MHz
6kHz ~ 100kHz
Resolution 1Hz 1Hz 1Hz
Basic Accuracy ±(0.01%+1d) ±(0.01%+1d) ±(0.1%+2d)
Overload Protection: 600V rms
Capacitance Ranges 2nF ~ 2mF 2nF ~ 2mF 10nF ~ 10mF
Resolution 1pF 1pF 0.01nF
Basic Accuracy: ±(1.9%+8d)
Overload Protection: 600V rms
Temperature Ranges -20ƍ ~ 800ƍ
-40ƍ ~ 400ƍ (66RT only)
(66RT only)
Resolution
0.1ƍ 0.1ƍ
Basic Accuracy
±(1%+3ƍ)
±(1%+10d)
Overload Protection: 600V rms
GENERAL
N/A
N/A
N/A N/A
2 times/sec 2 times/sec 2 times/sec 3 times/sec
CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V CAT. III 600V, CAT. II 1000V
250 250 250 300
GENERAL:
Sampling Rate:
Overload Indication: "OL" or "-OL"
Low Battery Indication
Auto Power Off: Approx. 10 minutes
Operating Temperature: 0ƍ~50ƍ, Ŝ80%RH
Storage Temperature: -20ƍ~60ƍ
Temperature Coefficient: 0.15(Spec.Acc)/ƍ, <18ƍ or >28ƍ
Safety: IEC 61010 and designed to meet UL3111 specifications
Power Requirement: IEC LR03, AM4 or AAA Size 1.5V x 2
Battery Life: In hours (Alkaline battery)
Size: 74mm(W) x 156mm(L) x 44mm(H)
250 250 250 250
Also including Temp. adaptor and
Bead
probe
Also including Temp.
probe
Weight: In grams
Accessories:Test Leads, ZnC battery(installed) and manual