9
3. Press the trigger to open the transformer jaws and clamp one conductor only, make sure that the jaws is firmly
closed around the conductor , then read the display from the multimeter directly.
3-3 DC Current Measurement
1. Select the highest anticipated input (600A or 100A) by the function switch.
2. Insert the "Output plugs (red and black)" to the input terminals of a Multimeter.
Set the Multimeter to "DC 200mV or 2V" range.
3. Adjust the "DCA Zero Adj. knob" until the display shows "0".
4. For DC measurement , output is positive in the red plug when the current flows from the lower side to the upper
side of the transducer as shown in Fig. 2
5. Press the trigger to open the transformer jaws and clamp one conductor only, make sure that the jaw
is firmly closed around the conductor , then read the display from the multimeter directly.