Installation manual
Serial Interface Specifications
Apollo GX50/60/65 Installation Manual
53
APPENDIX E - SERIAL INTERFACE SPECIFICATIONS
This appendix includes the RS-232 serial port interface specifications.
The RS-232 serial interface configurations supported by the GX50/60/65 are listed in Table 5.
Instructions for configuring the serial port are included in the checkout procedure on page 25.
Table 5 RS-232 Serial Interface Selections
RX TX Comment
NONE NONE No input or output
NONE MOVMAP Moving map data output
NONE MAPCOM Moving map data output with SL40 comm data
ALTENC NONE Altitude encoder-converter data input, no output
ALTENC MOVMAP Altitude encoder-converter data input, moving map data
output
ALTENC MAPCOM Altitude encoder-converter data input, moving map data
output with SL40 comm data
KEYPAD NONE Keypad data input
KEYPAD MOVMAP Keypad data input, moving map data output
KEYPAD MAPCOM Keypad data input, moving map data output with SL40
comm data
FADC MOVMAP Fuel / Airdata input, moving map data output.
PC SETUP Used for factory test
NONE MovMap Argus 3000, 5000, 7000 and Shadin Digiflow, Miniflow,
Microflow
MOVING MAP OUTPUT
The format of the moving map data output is as follows. Definitions of the output data is
included in Table 6 and Table 9. A sample output message is included in Figure 18.
Baud rate: ..........................................9600
Data bits: ...........................................8
Stop bits: ...........................................1
Parity: ...............................................none
Output rate: .......................................approx. 1 seconds
Message length: ................................variable, approx. 83 to 484 characters
The serial output messages are in the following format.
<STX><id><data><it><id><data><it>...<id><data><it><ETX>
<STX> ..............................................ASCII “start of text” character (1 byte, 02h)
<id> ..................................................item designator (1 byte, from following table)
<data> ...............................................item data (format listed in following table)
<it> ...................................................item terminator (1 byte, 0Dh)
<ETX> ..............................................ASCII “end of text” character (1 byte, 03h)