User`s guide
APOGEE ELECTRONICS
27
Symphony64 PCI card – User’s Guide
Hardware Combinations - Rosetta 800, AD-16X (Standard Routing Only)
Set Symphony Source to PCI Card 1, Port 1 (ch 1-32)
The AD-16X may be set to Standard or Advanced routing
PC-32 Connections
Settings
Routing
This combination offers 24 analog inputs and 8 analog outputs.To allow the routing of software outputs 1-2
to hardware analog outputs, connect the Rosetta 800 rst, then the AD-16X. Note that software inputs and
outputs 9-16 aren’t used, though they appear in your software program.
X-Symphony
THRU
X-Symphony
ROSETTAAD-16X
PORT 2PORT 1
MASTER
CHAN N ELS 1 - 32 CHAN N ELS 3 3 -64
VIDEO
Symphony64
MAC PROHARDWARE I/O
MAIN THRU
MAIN THRU
CHANNELS 9-16 UNUSED
HARDWARE I/0
AD16X STANDARD ROUTING
SOFTWARE IN SOFTWARE OUT
ROSETTA
AD-16X
ANALOG/DIGITAL IN 1-8
SymIn 1-8
SymIn 17-32
ANALOG OUT 1-8
ANALOG IN 17-32
SymOut 1-8
SymOut 17-32
CHANNELS 9-16 UNUSED
HARDWARE I/0
AD16X ADVANCED ROUTING
SOFTWARE IN SOFTWARE OUT
ROSETTA
AD-16X
ANALOG/DIGITAL IN 1-8
SymIn 1-8
SymIn 17-32
ANALOG OUT 1-8
ANALOG IN 17-32
DIGITAL OUT 17-32
SymOut 1-8