Specifications

Recording On To the DA-88 From an AD-1000
Using Video Sync
1. Connect the output of your console or microphones to the
AD-1000 XLR input connectors.
2. Select the appropriate analog input (+4 CAL, 10 CAL, or
MIC) on the INPUT SELECT switch.
3. Set the front panel power switch of the AD-1000 to ADAT
when using the Apogee FC-8 Format Converter. If using the
Tascam IF-88AE, select NORM for an AES output.
4. Set the SYNC SOURCE switch to the appropriate video
type NTSC, PAL or 60 Hz.
5. Connect an optical cable from the OPTICAL OUTPUT of
the AD-1000 to the ADAT IN of the FC-8. When viewing the
AD-1000 from the rear, the optical output is on the right side
or connect an AES cable from the AES output of the AD-
1000 to one of the AES inputs of the IF-88AE.
6. Connect a TDIF I/O cable, (Tascam part number PW-88D)
between the TDIF I/O connectors of the FC-8 and the DA-88.
7. Connect a 75 coaxial cable from your video sync gener-
ator to the SYNC INPUT BNC on the rear of the AD-1000,
making sure that DIP switch number 1 is on (input is termi-
nated), if this is the last device in the chain.
8. Connect a 75BNC cable from the WC output of the FC-
8 (or the IF-88AE) to the Word Sync input of the DA-88.
9. Set the CLOCK of the DA-88 to WORD
(not VIDEO).
10. Select DIGITAL IN on the DA-88 and arm
the desired tracks. Remember that the left
channel of the AD-1000 will go to tracks 1,
3, 5 and 7, while the right channel goes to
tracks 2, 4, 6 and 8 of the DA-88.
AD-1000 Operating Manual
Page 42
AD-1000 FC-8 DA-88
DA-88
Optical
Out
TDIF In
Fiber-Optic
Cable
Word Sync In
WC Out
ADAT In
FC-8
TDIF I/O
PW-88D
Sync Source XTAL
Sample Rate
44.1 / 48 kHz
Power Sw: ADAT
AD-1000 FC-8 DA-88 Video Sync
DA-88
Optical
Out
TDIF In
Fiber-Optic
Cable
Word Sync In
WC Out
ADAT In
FC-8
TDIF I/O
Video Sync Gen
PW-88D
Terminate with
DIP Switch #1
or 75 BNC
terminator