Specifications

Advanced Operations
The DIP Switches Location and Function
There are eight small switches located on the top of the unit that are accessible with a small screwdriver or pin
The default position is with all switches set to the off position. The switches serve the following functions.
Switch 1 Selects the termination of the SYNC-S/PDIF BNC connector located on the back of the AD-1000
Off Sync/SPDIF input is bridged with > 5k
On Sync/SPDIF input is terminated with 75
Switch 2, 3 and 4 Select the oscillator level output and 12 LED Threshold.
(The related Front Panel LED will light when in Oscillator mode.)
Level Below dB Full Scale Switch 2 Switch 3 Switch 4 LED Display
20 Off On Off Left 12
18 Off On On Left 2
16 On Off Off Left Over
15 Off Off Off Right Over
14 On Off On Right 12
12 On On Off Right 2
0 On On On All On
Audio Black Off Off On All Off
Switch 5 Selects the polarity of the Analog XLR Inputs
Off Pin 2 Hot (Pin 3 LED off*)
On Pin 3 Hot (Pin 3 LED on*)
Switch 6 Selects the UV22 Process Level (Appendix I, page 46 has more information regarding this selec-
tion)
Off Normal*
On Low*
Switch 7 Selects which gain potentiometer controls the microphone input level.
Off Front Panel Knob
On Multi-turn Calibration Pot
Switch 8 Selects which gain potentiometer controls the line input level.
Off Multi-turn Calibration Pot
On Front Panel Knob
*To differentiate between Pin 2 and Pin 3 Hot while in Low UV22 Mode, the following will occur: When Low
UV22 and Pin 3 Hot are set, the LED will turn OFF quickly every second or so. With Low UV22 and Pin 2 Hot,
the LED will turn ON quickly every second or so.
AD-1000 Operating Manual
Page 31