User`s guide

APOGEE ELECTRONICS
4
AD-16X – User’s Guide
Navigating the Front Panel
1
2
Figure 1
1) Power Switch - The POWER switch may be configured to operate in the manner best suited to the installa-
tion of the unit; for example, if the AD-16X is installed in a rack with a Master power switch, the unit may be
configured to power on when the Master switch is turned on. Please see the section of this manual entitled
“Internal Adjustments” for details.
Note that the POWER switch LED indicates that the AD-16X is receiving a proper AC input, and is in
Standby. The LED goes out when the AD-16X is powered on.
2) Setup buttons and LED - These buttons are used to modify all settings on the AD-16X. In general, setting
modification is accomplished by :
a) enabling Setup mode by pressing any of the 4 buttons (the Setup LED will light and one parameter
value will flash);
b) using the PREV or NEXT buttons to scroll to the parameter to be modified;
c) using the UP or DOWN buttons to select the desired parameter value.