User`s guide
APOGEE ELECTRONICS
4
AD-16X – User’s Guide
Navigating the Front Panel
1
2
Figure 1
1) Power Switch - The POWER switch may be configured to operate in the manner best suited to the installa-
tion of the unit; for example, if the AD-16X is installed in a rack with a Master power switch, the unit may be
configured to power on when the Master switch is turned on. Please see the section of this manual entitled
“Internal Adjustments” for details.
Note that the POWER switch LED indicates that the AD-16X is receiving a proper AC input, and is in
Standby. The LED goes out when the AD-16X is powered on.
2) Setup buttons and LED - These buttons are used to modify all settings on the AD-16X. In general, setting
modification is accomplished by :
a) enabling Setup mode by pressing any of the 4 buttons (the Setup LED will light and one parameter
value will flash);
b) using the PREV or NEXT buttons to scroll to the parameter to be modified;
c) using the UP or DOWN buttons to select the desired parameter value.
CH
3
CH
16
CH
2
CH
1
P NP NP NP N
SOFT LIMIT CHANNEL SELECT MODE
etc...
CH
3
CH
16
CH
2
CH
1
P NP NP NP N
CHANNEL CAL MODE
etc...
CH
5-6
CH
15-16
CH
3-4
CH
1-2
P NP NP NP NP N
UV22 CHANNEL SELECT MODE
etc...
Clock
Source
Sample
Rate
WC
Ratio
UV22
Soft
Limit
Global
CAL
AES
Format
P NP N P N P N P N P N P N P N
P N
PREV
NEXT
PRIMARY PARAMETER LOOP
Press and hold
PREV or NEXT
Press and hold
PREV or NEXT
Press and hold
PREV or NEXT