User Manual
Monitor Control Center
Symphony I/O Mk II is equipped with several monitoring features to provide for your monitoring needs.
How to set the Monitor Outputs as a fixed Line-Out
This setting changes the Monitor Outputs from a variable volume controlled by the control knob to a fixed output at the
full +4dBu or -10dBV reference level. This setting is convenient for connecting Symphony to an external monitor
control device such as a mixer or control center.
1.
Open Maestro and click the
“Output” tab
(or use the keyboard
combination [⌘+2]).
2.
In the Speaker Output section click the Speaker Output drop-
down box and select “Line”.
Note: This disable’s Symphony’s Monitor Output level control.
How to Setup and Use Multiple Speaker Sets
It is possible to connect up to three pairs of speaker monitors and toggle between them. This is very useful to check
how a mix sounds through different speakers and systems.
1.
Connect the first pair of speakers to analog outputs 1-2, the second pair to outputs 3-4, and if desired, a third pair
to outputs 5-6.
2.
Open Maestro and click the
Output tab (or use the
keyboard combination [⌘
+2]).
3.
From the Speaker Output
Select drop-down box,
select “2 Speaker Sets” or
“3 Speaker Sets”.
4.
Click the Speaker Set 1, 2,
or 3 button to select which
speaker set is active.
Note: To activate multiple speaker sets simultaneously, hold down [command ⌘] and select another speaker set
button.
SYMPHONY I/O MK II - USER’S GUIDE Page 24