How to Guide

VOC: <400 g/L (regulatory)
HANDLING PRECAUTIONS: Store product in the cargo area of vehicle, and secure on
top of 6 mill plastic sheeting to prevent damage due to accidental spills. Product
safety information required for safe use is not included. Before handling, read product
safety data sheets and container labels for safe use and for physical and health hazard
information. Safety Data Sheets are available on the APOC website at www.apoc.com,
the APOC APP, by contacting APOC at technicalinfo@apoc.com or calling (813) 248-
2101.
LIMITED WARRANTY AND DISCLAIMER: To the best of our knowledge, the technical data
contained herein is true and accurate at the date of issuance and is subject to change
without prior notice. User must contact APOC to verify correctness before specifying or
ordering. No guarantee of accuracy is given or implied.
APOC Roong Systems, Inc. (herein “APOC”) hereby warrants to the original purchaser,
contingent upon original proof of purchase, that this product will be free from any
and all manufacturing defects that may materially and adversely affect the product’s
performance for a period of one (1) year from the date of original purchase (“Warranty
Period”). Product must be applied in accordance with the proper application procedures,
and for the intended use as stated on the label. Proper preparation and drying conditions
must be observed to achieve correct results. Should a manufacturing defect materially
and adversely affect this product’s performance, APOC shall, within its sole discretion
and upon receipt of Purchaser’s timely written notice within the Warranty Period,
provide replacement product(s) or refund the purchase price of the defective product.
THIS LIMITED WARRANTY IS PURCHASER’S SOLE AND EXCLUSIVE WARRANTY
AND REPLACES ALL OTHER WARRANTIES, CONDITIONS, REPRESENTATIONS AND
GUARANTEES, WHETHER EXPRESS OR IMPLIED, WHETHER BY STATUTE, AT LAW
OR IN EQUITY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. This limited warranty does not cover labor or
installation costs, water damage, consequential damages or incidental damages. Under
no circumstances will APOC be liable for any amount in excess of the product purchase
price. Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you. This warranty gives you specic legal rights,
and you may also have other rights which vary from state to state. Direct all warranty
claims in writing along with original proof of purchase to APOC, c/o Warranty Claims
Department, P.O. Box 5449, Tampa, FL 33675. The exclusive venue for any legal action
arising out of the purchase of this product or this warranty shall be had in a court of
competent jurisdiction within Hillsborough County, Florida. Florida law shall govern. For
additional Limited Warranty information, visit www.apoc.com/pages/warranty.
LIMITED EXTENDED WARRANTY ELIGIBILITY REQUIREMENTS: For information and
eligibility requirements for APOC Roof Systems, Corp. (“APOC”) LIMITED EXTENDED
WARRANTIES, visit www.apoc.com/pages/extendedwarranty. EXTENDED WARRANTIES
vary by product and application rates and are not available for all products.
Approx. Shipping Weights: (Note: All approx. weights include container)
10 . oz tube (296mL) 1 lb.
12 tubes/case 7.9 lbs.
1 gallon (3.8L) 11 lbs.
3 gallons (11.36L) 32 lbs.
Gardner-Gibson, Inc. • P.O. Box 5449 • Tampa, Florida 33675-5449
Phone: (813) 248-2101 • Fax (813) 248-6768 • www.apoc.com
F-18
COMPLIANCE: Exceeds performance requirements of ASTM D4586, ASTM
D3409, ASTM D6511. Miami-Dade County Product Control Approved.
DESCRIPTION: APOC
®
501 Super-Flash
®
Roof & Flashing Sealant is a unique
professional grade elastomeric ashing and repair product that cures to a long
lasting rubber and elastic repair. This 50 year product is designed to provide a
exible seal through extreme temperature ranges. Its non-sag properties and
exceptional adhesion guarantee that Super-Flash is the ideal product for the
construction and repair of all ashings, parapet walls, copings and chimneys.
This product is ideally suited for sealing splits, cracks, holes and built-up
roofs (asphalt and coal tar), and modied bitumen membranes. It may also
be used as a topical repair for EPDM rubber sheets. Super-Flash can be used
to seal leaks on damp or wet surfaces and even works as a temporary repair
in standing water. This is not designed as an adhesive product. Do not use for
adhering shingle tabs or any other roong materials.
PREPARATION: Download the APOC APP for detailed installation instructions,
videos, tips and specications. Completely read all application instructions
and check weather conditions prior to starting any work. All surfaces must be
completely clean, have proper drainage and be free of surface rust, dust and
any other foreign matter. For longevity and UV protection, it is recommended
to protect repairs with the application of a reective coating after they have
cured for 30 - 90 days. DO NOT HEAT OR THIN products.
FOR BEST RESULTS: Apply when surface temperatures are between 40 °F and
120 °F. In colder weather, product should be stored in heated room (65 °F to
80 °F.) at least 24 hours prior to application. Product formulated to be used
year-round.
FALL PROTECTION WARNING: Always use personal fall protection devices
and follow procedures in accordance with OSHA and local regulatory
requirements when walking or working on roofs. Use safety equipment such
as tie-offs, safety lines, body harnesses, toe boards and ladders. Dusty, damp
or wet conditions as well as certain shoes can result in slippery surfaces
and create a fall hazard. Always be cognizant of where you are in relation
to your surroundings, including but not limited to: the edge of the roof, any
projections, skylights and any other objects which could cause you to slip or
fall. Falling from a roof can result in serious harm or death.
APPLICATION: For exterior use only. Protective clothing, gloves and eyewear
should be used during application of these products. Puncture foil seal
at inner base inside the nozzle. Apply with a caulking gun and if needed,
smooth with a putty knife. Work material to an even consistency over and
into the area to be repaired. Apply 1/4” thick, two or three inches beyond
the problem area. It is highly recommended to reinforce the repair with a
strip of APOC reinforcing fabric. Embed fabric into the cement and cover
with a second layer of cement. Form a feathered edge with cement where
chimneys, vent pipes, and other projections meet the roof line.
CLEAN-UP: Tools are best cleaned with Xylene, but paint thinner or mineral
spirits will work on fresh product.
TYPICAL PHYSICAL & PERFORMANCE CHARACTERISTICS:
Weight Per Gallon 10.1 lbs.
Residue by Evaporation 65%
Elongation (ASTM D562) 250% min.
Permeability (ASTM D1653) <5 Perms
Adhesion to Polyurethane Foam Excellent
Combustible Solvents Xylene
Consistency Trowel
Skin Time (50% Relative Humidity, 70 ˚F) 15 minutes
Full Cure (50% Relative Humidity, 70 ˚F) 7 - 10 days
Application Temperatures 40 ˚F - 110 ˚F
Clean-up Xylene
SUPER-FLASH
®
RooF & FLASHing SEALAnt
DAtA SHEEt
AP 501
©2018 Gardner-Gibson, Inc.
Manufactured by / Fabricado por:
Gardner-Gibson, Inc.
P.O. Box 5449, Tampa, FL 33675
See SDS for more info
*Individual product weights may vary +/- 10%.