Installation Manual

29
Confidential – API Healthcare Corporation Configuration Settings
Copyright © 2006. All rights reserved. 2008-04-29
[1] Change IP Port Configuration. Enter 1 to configure the IP Port configuration. Select [2] for UDP. Press
enter to reach the option 'Please enter the UDP remote port. Enter the value and press Enter to complete the
entry. The other settings are not used.
For the Remote Port, when the value is configured with 0, the device acquires the value configured within
the communications software. When the value is configured manually, it must match the value in the
communications software. 0 is the default.
Your Command[1 – 7]: 1
Please select an IP port type:
[1] TCP
[2] UDP
Type[1 – 2]: 2
IP Port set to: UDP
Please enter the UDP local port:
Please enter the UDP remote port(0 for any port): 0
UDP Remote Port set to:10100
Please enter the UDP packet idle time(10ms units):
[2] Restart Device. Enter 2 to reset the CPUs operating on the device. This option does not clear any data, it
only restarts the device.
[3] Load Factory Default Settings. Enter 3 to reset the device using the factory default. This clears any
configuration data including the IP settings, badge configuration, and prompt data.
[4] Load Saved Settings. Enter 4 to reload the settings currently saved on the device.
[5] Change Password. Enter 5 to configure a new device password. Password must be between 1 and 20
characters.
[6] Return to Main Menu. Enter 6 to return to the main menu.
[7] Save changes and Exit. Enter 7 to save changes and exit from the Telnet session.
[8] Exit Without Saving Changes. Enter 8 to exit from the Telnet session without saving any changes.
[3] Save Changes and Exit
Select Menu option 3 to save any changes configured and exit the Telnet menu.
[4] Exit Without Saving Changes
Select Menu option 4 to exit the Telnet menu without saving any changes you may have configured.