Specifications
16721-1
11/21/2012 10:16 AM
SECTION 16721
VIDEO SYSTEM
PART 1 GENERAL
1.01 DESCRIPTION
A. This section of the specification includes the furnishing, installation, connection and
testing of the video system.
B. These specifications and associated drawings constitute the minimum requirements.
C. Underwriters Laboratories Inc. (UL) - USA: System components shall be UL listed.
D. Specialty providers shall include:
1. System shall be based on IV&C Longwatch System with HD IP Cameras
and computer based video recording system. The Local manufacturer’s
representative is InSources, 877-467-6872.
2. CC Controls shall be responsible for the video system; the services of special
video system Contractor (for installation), Mike Cronin of Contractor Alarm
Services (561 747-3861) shall be a sub-Contractor to CC controls.
3. The services of Gary Yocum, P.E. of WSW (321-230-3716) to verify and
confirm the spare pair of fiber optic, communications between the
Generator Building and the Operations Building, locate and label the spare
fibers for the video system use.
1.02 SCOPE
A. The system shall be installed in accordance to the project specifications and
drawings.
B. Basic Performance (minimum requirements):
1. All cameras shall be weather proof, IP based, with daytime and nighttime
CMOS with progressive scan. Color when adequate light levels exist.
Cameras shall auto switch to black and white when low levels exist.
Cameras shall be used indoors at temperature not to exceed 105˚F. Cameras
shall use indoor lighting.