Specifications
ISSUED FOR: PROPOSAL PURCHASE AS BUILT
FACILITY NAME/LOCATION:
ITEM NAME: PURCHASER/LOCATION:
ITEM TAG NO.: JOB NO.:
SERVICE: PURCHASER ORDER NO.:
UNIT: SUPPLIER/LOCATION:
DWG. NO.: SUPPLIER ORDER/SERIAL NOS.: /
DATA PROVIDED BY: PURCHASER SUPPLIER
SUPPLIER IF NOT BY PURCHASER
REFER TO PIP ELSAP20 FOR GENERAL REQUIREMENTS
APPLICABLE STATE AND LOCAL CODES:
SITE CONDITIONS:
ENCLOSURE (4.6):
ALTITUDE: FT SEISMIC ZONE: NEMA 1 WALL MOUNTED FLOOR MOUNTED
AMBIENT TEMPERATURE: MAX.: °C MIN.: °C OTHER:
AREA CLASSIFICATION: UNCLASSIFIED OTHER: FINISH: SUPPLIER STANDARD OTHER:
OTHER: SPACE HEATER NOT REQUIRED (4.6.2)
GENERAL (4.1):
PURCHASER SUPPLIER
MOUNTING (4.1.1): INDOOR OUTDOOR TEMPERATURE CONTROL (4.6.2.6):
IN MCC IN SWITCHGEAR ADJUSTABLE THERMOSTAT CONTROL
OTHER: HIGH TEMPERATURE CUTOUT
BYPASS ISOLATION SWITCH REQUIRED (4.1.2) MOMENTARY TEST PUSHBUTTON AND AMMETER (4.6.2.7)
PERMIT USE OF MOLDED CASE CB'S (4.1.3)
SILVER PLATED OTHER: INSPECTION AND TESTING (4.7):
TRANSFER SWITCH (4.2): SUPPLIER'S STANDARD TESTS
VOLTS PHASE POLES HERTZ OTHER:
AMPERES: FAULT CURRENT (4.2.2):
OPEN TRANSITION (4.2.3) WITNESSED
CLOSED TRANSITION (4.2.4) SHIPPING (4.8):
DELAYED TRANSITION (4.2.5) SUPPLIER'S STANDARD PREPARATION
SWITCHED NEUTRAL CONDUCTOR (4.2.14) OTHER:
SOLIDLY CONNECTED NEUTRAL CONDUCTOR (4.2.15) DOCUMENTATION (4.9):
MICROPROCESSOR CONTROLLER (4.4): ELECTRONIC DOCUMENT FORMAT:
TRANSFER TO ALTERNATE SOURCE (4.4.10) 85% VOLTAGE DXF OTHER:
OTHER: MANUFACTURER TO PROVIDE:
90% VOLTAGE REPRODUCIBLE PLUS:
OTHER: COPIES OF ALL DOCUMENTATION PLUS:
TRANSFER TO ALTERNATE SOURCE (4.4.11) 90% OF FREQUENCY COPIES OF OPERATING MANUALS
OTHER: OTHER REQUIREMENTS:
RE-TRANSFER TO NORMAL SOURCE (4.4.11) 95% OF FREQUENCY
OTHER:
RE-TRANSFER TO NORMAL SOURCE (4.4.14) MANUAL
AUTOMATIC
COMMUNICATION (4.4.3)
RS485 OTHER:
OPTIONAL FEATURES (4.5):
GREEN/RED SIGNAL LIGHTS (4.5.1)
AUXILIARY CONTACTS (4.5.2)
CONTACT FOR LV ENGINE START SIGNAL (4.5.3)
TEST SWITCH FOR NORMAL SOURCE FAILURE (4.5.4)
PUSH-TO-TEST INDICATOR LIGHTS (4.5.5)
PUSH BUTTON TO TEST ALL (4.5.5)
ENGINE EXERCISER (4.5.6)
NO. DATE REVISION DESCRIPTION BY APVD.
1RE-TRANSFER TO NORMAL SOURCE (4.4.10)
POWER FOR SPACE HEATER:
DATA SHEET
ASSOC. PIP
ELSAP20
ELSAP20D-D
PAGE 1 OF 1
JUNE 2007
LOW-VOLTAGE AUTOMATIC
TRANSFER SWITCH
INTERCONNECTION (4.1.5):
✔
East Central Regional Water Reclamation Facility - West Palm Beach, Florida
Automatic Transfer Switch
ATS1
43-42-11-29 (SHEETS E-01-0 THRU E-05-0)
BELOW 3300 N/A
✔✔
40 -5
✔
✔
✔
✔
✔
✔
360480 3
✔
600 50,000A
✔
✔
✔
✔
PDF/DWG
2
2
✔
DEVICENET
✔
✔
✔
✔
✔
✔