Instruction manual
NOTICE: CAUTION: This safety symbol is used to
indicate a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
NOTICE: LEL sensor should be checked for accuracy after
exposure to any gases containing silicones, high sulfur content,
high concentrations of propane and high concentrations of CO
(above 1000ppm) or exhaust gases.
Continuously low calibration check results or fluctuation of zero
readings may indicate sensor end of life or failure. Consult SENSIT
Technologies with any questions.
For best accuracy always zero in clean air environments similar in
temperature and relative humidity to the environment where the
instrument will be used. When continuously exposed to
combustible gas concentrations beyond LEL for longer than 5
minutes always perform a calibration check prior to the next use.
WARNING: To reduce the risk of ignition of a flammable
atmosphere, batteries must only be changed in an area known
to be nonflammable.
WARNING: Do not mix batteries of different age or type.
WARNING: Not for use in atmospheres of oxygen greater
than 21%.
WARNING:
ONLY zero instrument in a gas free environment.
WARNING: To maintain intrinsic safety, service must be
performed by factory authorized technicians with approved
replacement parts only.
CONTENTS
Page # 1 Parts and Accessories
2 General Description
3 Specifications
4 Product Features
6 Sensor Types and Pumps
7 Battery Installation
8 Operation and Use
14 Bar Hole Test
15 Calibration Check (Bump Test page 21)
16 Menu
28 Calibration
33 Expert User Feature Chart
Back Warranty
PARTS AND ACCESSORIES
Standard Accessories (included)
Carrying Case, Alkaline Batteries, Wrist Strap, Extra Sensor Cap
with O-Rings and Instruction Manual
Accessories and Replacement Parts
ASG0150 Extension Adapter
AJN02039 Hydrocarbon Filter (10) (Barhole Probe with
filter required)
AJN02023 Hot Air Probe Assembly
AJN02017 81.3cm (32”) Fiberglass Bar Hole Probe w/Filter
AJN02013 Confined Space Probe with Tubing
AJN02021 Printer
AJN02033-PCIS PC Interface with Software
CSC00100 SMART-CAL™ Automatic Calibration System
PJN0110 Sensor Cap with O-Rings
Calibration Kits Contact factory for correct kit