3.9.3.2.1 CabinetPowerCalibrate
SeeSections"5.9AnalogPowerCalibrations"onpage5‐12and"5.10DigitalPowerCali brations"onpage5‐21for
proceduresthatutilizethisscreen.
Figure 3-30 Cabinet Power Calibrate Screen
TheCalboxescanbeselectedtoopenupakeyboardentryscreen.TheVSWREnableandDisablebuttonsareused
duringreflectedpowercalibration.TheprocessisdescribedinSection5.
3.9.3.2.2 ServiceModeScreen
Warning
SERVICE MODE IS TO BE IMPLEMENTED ONLY WHILE SERVICING THE COOLING
SYSTEM! FAULTS MUST BE RESET TO ’ENABLED’ AT ALL OTHER TIMES. FAILURE
TO DO SO MAY RESULT IN SERIOUS DAMAGE TO THE TRANSMITTER!
Figure 3-31 Service Mode Screen
Press’Enable’buttonstodisableindicatedfaultprotection.Pressagaintoenablefaultprotectionimmediatelyon
completionofservicing.Beforedisablinganyofthethreefaultsnormaloperationmustbeconfirmed.Forexample,
shouldtheflowmeterfaultbedisplayedtheoperatormustconfirmthatthefaultiscausedbya
badflowmeter
componentandthatadequateflowispresentinthecoolingsystembeforedisablingthefault.Thefaultshouldbe
enabledassoonasthebadflowmetercomponentisreplaced.