3.9.3.2 CabinetSetup
Thecabinetpowerlevels,lowpowerwarning,numberofPAs,andthenumberofliquidcoolingpumpsissetinthe
cabinetsetupscreen.
Figure 3-29 Cabinet Setup Screen
Table312TCUHome>System>Service>SystemSetup>CabinetSetup
Field Explanation
CabFWDPwrOut(W)
Setcabinetnominaloutputpowerhere.Thisisthepoweroutofthecabinetbeforethe
combinerorfilter.Thisneedstobesetforeachcabinet.Setscabinetnominalpowerusedto
setALClevel.Maximumcabinetpowerislimitedto10%overthisvalue.
LowWarnThreshold Whenthecabinetforwardoutputpowerreachesthislevel,alowpowerwarningisproduced
NumberofPAs EnterthenumberofPAmodulesintheselectedcabinet.Thisneedstobesetforeachcabinet.
CoolingPumps
Setthistoeither1or2dependingonhowmanypumpsareinthepumpmoduleforthis
cabinet.Thisneedstobesetforeachcabinet.