Specifications
Section-3 Operation
November 11, 2013
3‐16
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
a. OK‐Greenbackground
b. Fault‐Redbackground
c. OFF‐Thebackgroundisgray.
TheOn/Offfieldcanbeusedtotoggleindividualamplifiermodulesonoroffasneeded.
Note
Always be sure that you are accessing the desired cabinet number. The cabinet being viewed is indicated
in the upper left corner of the screen.
TogetdetailedinformationonaparticularPAModule,presstheFaultsbuttonontherightsectionofthescreen.The
FaultsbuttonwilltakeyoutothePAFaultsscreenshownin
Figure3‐15.
3.6.1 PAFaults
ThisscreenisbasicallyalistofallfaultsmonitoredineachPAModule.
• Anactivefaultwillbehighlightedinred
• Awarningconditionwillbehighlightedinyellow .
Note
For a detailed explanation of all PA Faults in Figure 3-15 refer to Section 6, Diagnostics.
Formulticabinettransmitters,pressingtheNextCabinetbuttontogglesthedisplaybetweenthevariousPA
cabinets.
Figure 3-15 PA Faults Screen
PAModuleswillfaultoffatapproximately90Wreflectedpower.Also,itwilldisplayatemperaturefaultat65°C
ambienttemperature(measuredbyathermistoronthemonitorboard)or90°Cpallettemperature.
3.7 OutputMainScreen
IfyoupresstheOutputbuttonontheHOMEscreen,itwilltak e youtothescreenshownin
Figure3‐16.TheOutputMenustructureisshowninFigure3‐7onpage3‐9.
Formulticabinettransmitters,pressingtheNextCabinetbuttontogglesthedisplaybetween
thevariousPAcabinets.
ToFigure3‐14