Specifications

Maxiva ULX Series
November 11, 2013
37
8882628300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
TCUsallowfortwosimultaneousengineerlevelusers.TCUusernames,passwords,andaccesstimecanbesetand
changedbyAdministratorlogin.SeeSection3.2.2,TCU‐InitialLogin&Passwords,onpage32.
3.3.3 GlobalStatusandNavigation
Thetop2sectionsofthetouchscreendisplay(darkbluebackground)areconsideredglobalbecausetheyshowup
onallscreens.Thetoplineindicatesthetransmitternameandmodelnumber.
Figure 3-6 Global Display Header
Thesecondlineofthedisplayhasoperationalandstatusinformationincluding:
a. ON,Standby,FaultOFF,ON/FB(transmitterfoldback),PSMUTE,andRFMUTEstatusindication.
ON:Normaloperatingmode
Standby:Transmitterturnedoffmanuallyorremotely
FaultOFF:Transmitterforcedoffduetofaultcondition
ON/FB:Transmitterpowerfoldedback.Conditionscausingthefoldbackmaybytemporary
andcouldpossiblybeclearedbypressingtheONbutton.If,afterpressingtheONbuttonto
resetthefoldback,theON/FBindicationresumesthemalfunctionwillneedtobe
determinedandthetransmitterrepaired(seeSection6for
faultloglistings).
PSMUTE:Atemporaryfaultconditioncausedbyapowersupplyrelatedfault.Ifunderlying
faultclears,themuteconditionwillbelifted andthetransmitterreturnedtonormal
operatingmode.Ifthemutecontinues,theunderlyingfaultwillneedtobedetermined
andthetransmitterrepaired(seeSection6for
faultloglistings).
RFMUTE:AtemporaryfaultconditioncausedbyanRFrelatedfault.Ifunderlyingfault
clears,themuteconditionwillbeliftedandthetransmitterreturnedtonormaloperating
mode.Ifthemutecontinues,theunderlyingfaultwillneedtobedeterminedandthe
transmitterrepaired(seeSection6forfault
loglistings).
Table33LoginParametersTCU&LPU
Unit Username Password
TCUAdministrator admin
admin(default,mustbesetbyuser,seeSection3.2.2,
onpage32).
TCUEngineer1Setbyuser. Setbyuser.
TCUEngineer2Setbyuser. Setbyuser.
System Forward Power Bargraphs
Transmitter Model Number
Fault & Operational
Status
Forward or Reflected
Sound or Reflected
100% Mark - Based on
Nominal Power Output setting
in System Setup screen
Power Bargraph
Power Out
Login Soft Key
Logged in as Engineer,
press soft key to logout.