Specifications

Section-3 Operation
November 11, 2013
32
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
onpage238.Beforeaccessingthetransmitterviaremotewebbrowserinterfacethefactorydefaultpasswordmust
bechangedlocallyusingthefrontpanelPCtouchscreen.
3.2.2 TCU‐InitialLogin&Passwords
TherearethreeTCUpasswordlevels:
Administrator:Allowsoneuseraccesstochangepasswords.
Engineer:TwouserscanaccesstheTCUeachusingadifferentEngineerlevelpassword.Engineerlevelallows
fullaccesstothetransmittertoviewscreensandmakechangestosettings.
Guest:MultipleguestleveluserscanaccesstheTCUtoviewallscreens.Guestuserscanmakenochanges.No
usernameorpasswordentryisrequired.
Note
Transmitters that contain a TCU require setup of TCU passwords prior to the use of the remote web
browser:
STEP 1 WithACpowerappliedtothetransmittercomponents,touchthepanelPC
screentoactivateit.TheTCUHomescreenwilldisplayasshowninFigure39
onpage311.
STEP 2 PresstheLoginbuttonintheupperleftcorneroftheTCUHomescreen.This
willopentheLoginscreenshowninFigure35onpage36.
STEP 3 LoginasAdministratorbyenteringtheusernameadminandthepassword
admin.Thescreenshownontheleftin
Figure32willopen.
Figure 3-2 TCU Admin Screens
STEP 4 PresstheEditbuttontodisplaythescreenshownontherightinFigure32.
STEP 5 PresstheAdminPasswordboxandtouchscreenkeyboardwillopenallowing
entryofanewadminpassword.Enterthedesiredadminlevelpasswordand
pressdone.Oncechangedthenewadminlevelpasswordwillallowthe
administratortochangepasswordsremotely.
Note
The Admin level default username admin can not be changed.