Specifications
Maxiva ULX Series
November 11, 2013
2‐35
888‐2628‐300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
2.18.3 RemoteStatusOutputsJ6,J7&J8
Alloftheremotestatusoutputsareopencollectorandwillsink100mAatupto+24Vdctoprovideanindication
statusisactive.ThepullupsupplyvoltageforthestatusindicationscanbesuppliedviaJ6,J7&J8orcanbesupplied
byanexternalvoltagesource.The
statusoutputconnectionsarelistedinTable2‐13
.
J5‐1
J5‐2 PowerControlAutoSelect PulsedLOW
J5‐3 PowerControlManualSelect PulsedLOW
J5‐4 GROUND
J5‐5 RFSwitchASelect PulsedLOW
J5‐6 RFSwitchBSelect PulsedLOW
J5‐7 GROUND
J5‐8 NC
J5‐9 NC
J5‐10 NC
J5‐11 NC
J5‐12 NC
Table2‐13J6,J7&J8CustomerI/OBoard,Re mo te StatusOutputs
Connectorandpin# StatusOutput StatusTypeandPolarity
J6‐1 GROUND
J6‐2 TransmitterOFF/ONStatus
L=ON
H=OFF
J6‐3 ExciterA/BActiveStatus
L=BON
H=AON
J6‐4 ExciterAUTO/MANUALStatus
L=AUTO
H=MANUAL
J6‐5 GROUND
J6‐6 IPAA/BActiveStatus
L=BON
H=AON
J6‐7 IPAAUTO/MANUALStatus
L=AUTO
H=MANUAL
J6‐8 GROUND
J6‐9 PumpA/BActiveStatus
L=AON
H=BON
J6‐10 PumpAUTO/MANUALStatus
L=AUTO
H=MANUAL
J6‐11 GROUND
J6‐12 GROUND
J7‐1 GROUND
J7‐2 RemoteControlENABLED/DISABLEDStatus
L=RemoteENABLED
H=RemoteDISABLED
Table2‐12J3,J4&J5,CustomerI/OBoard,Re mo te ControlConnectors
Connectorandpin# Function CommandTypeandPolarity