Specifications
Section-2 Installation
November 11, 2013
2‐34
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
ExternalParallelremotecontrolunitscaninterfaceattheCustomerI/OBoardatthetopofthecabinet.J13through
J17areforremoteControl,StatusandAnaloguereadings.Theconnectorsareorganizedasfollows:
• J3,J4andJ5‐RemoteTransmitterControlFunctions
• J6,J7andJ8‐RemoteStatusOutputs
• J9‐RemoteAnalogueMeteringOutputs
Note
The forward slash (/) in front of a signal name means active low. The signal named "/INPUT 1" for exam-
ple is activated by bringing that input low. Signal names without the forward slash are considered active
high. This convention is used throughout the schematics.
2.18.2 TransmitterControlFunctionsJ3,J4andJ5
Allcontrolinputsuseopto‐isolatorsforsurgeprotection.Theopto‐isolatorsarepoweredbyaninternal+5Vdcfrom
anisolationprotectioncircuit.
Alltransmittercontrolfunctions(exceptRemoteRFMute,RFSwitchPositionAandRFSwitchPositionB,which are
activeLOWorHIGHlevelinputstates)aremomentarygroundswitchingandrequiretheremotecontrolequipment
tosinkatleast15mAtoactivatethefunction.ThepinoutsofJ3,J4and
J5arelistedinTable2‐12.
Table2‐12J3,J4&J5,CustomerI/OBoard,Re mo te ControlConnectors
Connectorandpin# Function CommandTypeandPolarity
J3‐1 GROUND
J3‐2 TransmitterON PulsedLOW
J3‐3 TransmitterOFF PulsedLOW
J3‐4 RAISEPower PulsedLOW
J3‐5 LOWERPower PulsedLOW
J3‐6
J3‐7 GROUND
J3‐8 ExciterASelect Pulse dLOW
J3‐9 ExciterBSelect PulsedLOW
J3‐10 ExciterAutoSelect PulsedLOW
J3‐11 ExciterManualSelect PulsedLOW
J3‐12 GROUND
J4‐1 GROUND
J4‐2 IPAASelect PulsedLOW
J4‐3 IPABSelect PulsedLOW
J4‐4 IPAAUTOSelect PulsedLOW
J4‐5 IPAMANUALSelect PulsedLOW
J4‐6 GROUND GNDA
J4‐7 PumpSwitchCommand PulsedLOW
J4‐8 SPARE
J4‐9 PumpAutoSelect PulsedLOW
J4‐10 PumpManualSelect PulsedLOW
J4‐11 GROUND GNDA
J4‐12 GROUND GNDA