Specifications

Section-2 Installation
November 11, 2013
234
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
ExternalParallelremotecontrolunitscaninterfaceattheCustomerI/OBoardatthetopofthecabinet.J13through
J17areforremoteControl,StatusandAnaloguereadings.Theconnectorsareorganizedasfollows:
J3,J4andJ5‐RemoteTransmitterControlFunctions
J6,J7andJ8‐RemoteStatusOutputs
J9‐RemoteAnalogueMeteringOutputs
Note
The forward slash (/) in front of a signal name means active low. The signal named "/INPUT 1" for exam-
ple is activated by bringing that input low. Signal names without the forward slash are considered active
high. This convention is used throughout the schematics.
2.18.2 TransmitterControlFunctionsJ3,J4andJ5
Allcontrolinputsuseoptoisolatorsforsurgeprotection.Theoptoisolatorsarepoweredbyaninternal+5Vdcfrom
anisolationprotectioncircuit.
Alltransmittercontrolfunctions(exceptRemoteRFMute,RFSwitchPositionAandRFSwitchPositionB,which are
activeLOWorHIGHlevelinputstates)aremomentarygroundswitchingandrequiretheremotecontrolequipment
tosinkatleast15mAtoactivatethefunction.ThepinoutsofJ3,J4and
J5arelistedinTable212.
Table212J3,J4&J5,CustomerI/OBoard,Re mo te ControlConnectors
Connectorandpin# Function CommandTypeandPolarity
J31 GROUND
J32 TransmitterON PulsedLOW
J33 TransmitterOFF PulsedLOW
J34 RAISEPower PulsedLOW
J35 LOWERPower PulsedLOW
J36
J37 GROUND
J38 ExciterASelect Pulse dLOW
J39 ExciterBSelect PulsedLOW
J310 ExciterAutoSelect PulsedLOW
J311 ExciterManualSelect PulsedLOW
J312 GROUND
J41 GROUND
J42 IPAASelect PulsedLOW
J43 IPABSelect PulsedLOW
J44 IPAAUTOSelect PulsedLOW
J45 IPAMANUALSelect PulsedLOW
J46 GROUND GNDA
J47 PumpSwitchCommand PulsedLOW
J48 SPARE
J49 PumpAutoSelect PulsedLOW
J410 PumpManualSelect PulsedLOW
J411 GROUND GNDA
J412 GROUND GNDA