Specifications

Section-2 Installation
November 11, 2013
230
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
Note
Actual flow rate may deviate from recommended depending on site specifics like pipe diameter, number of
elbows, and run length. The flow rate must be above the trip point level in order to prevent frequent faults
and pump switches. .
Note
If the pump is unable to deliver the required flow rate, check for correct wiring of the 3 AC phases. Incor-
rect wiring of the 3-phase sequence would allow the pumps to operate but with much degraded perfor-
mance.
2.15.1.1 ConfirmationofAuto PumpSwitching
Oncetheinverter/controllerLL(lowlevel)issettheoperationofthetransmitterflowsensorcanbeconfirmedby
thefollowing:
STEP 1 SetHEpumpmoduletoRemote.
STEP 2 UseSystempageGUItoselectAutopumpcontrolmode.Thisactivates
automaticpumpswitching.
STEP 3 Turntransmitteron.
STEP 4 Reducetheflowratethroughthecabinetbyslowlyclosingthecabinet
coolantinletvalve.Whentheflowratethroughthecabinetfallsbelowthetrip
pointtheflowwarningshouldactivateandthesystemshouldswitchtothe
otherpump.
STEP 5 Gobacktothenominalflowraterecommendedforthecabinetbyslowly
openingthecabinetinletvalve.Thewarningshouldgoaway.
STEP 6 Endofprocedure.
2.15.2 HeatExchangerFanControl
Fanoperationiscontrolledbythefaninverter/controllers.Thecontrollersautomaticallychangethefanspeedbased
ontemperaturesensedintheheatexchangersupplyline.Thefansturnatalowspeedwhenthecoolant
temperatureis>30degreesC.andpowerisappliedtothetransmitterandpumpmodule.The
faninverter/
controllershavebeenprogrammedatthefactorysonosetupisrequired.
Note
If fan activation is needed to check fan rotation but the transmitter is not available, the fan inverter/con-
trollers must be set up for manual control to allow fan activation. This is accomplished by following the
procedure outlined in the HE pump module technical manual 888-2625-001 Section 3.1.4 on page 3-5.
Table211TypicalTransmitterFlowRate s
QuantityofPA
Modules
MinimumCoolantFlowRateTrip
Point(LPM)
RecommendedCoolant
FlowRate(LPM)
TypicalPumpFrequency
Range(Hz)
2 10 14 1520
3 19 27 1520
4 23 32 1525
6 31 43 2030
8 38 53 2535
10 46 65 TBD
12 53 75 TBD
16 70 100 TBD