Figure 2-14 PS Faults Screen
STEP 7 CustomizethetransmitterSystemSetup.System>SystemService>System
SetupontheGUI.TheSystemSetupscreendisplaysthesettingsforSystemPwr
Out,CenterFrequency(visualcarrierforanalogsystems),ModulationType,AC
LineVolt(VAC),Numberofexciters,NumberofCabinetsandExternalRF
Switch.Touchthescreenateachfield
toenterthedatapertinenttothesetting.
TheSystemSetupscreenisshowninFigure325onpage322.
STEP 8 CustomizethecabinetSetup.PressSystem>SystemService>System
Setup>CabinetSetupontheGUI.Touchthescreenateachfieldtoenterthe
correctdataforCABPwrOut(W),NumberofPA’s,NumberofIPAsandCooling
Pumps(numberpresent).TheCabinetSetupscreenisshownin
Figure329on
page326.
STEP 9 Endofprocedure.
2.15 CoolingSystemSetup
Followtheremainingstepstocompletethecoolingsystemsetup.
2.15.1 SettingtheTransmitterFlowRate
ThecoolantflowrateisdeterminedbytheHEpumpmoduleinverter/controllerfrequency.Ifothertypesofpump
moduleareusedtheflowrateiscontrolledbyadjustmentofthecabinetinletvalve.
TheflowratecanbecheckedviathetransmitterGUI.PressSYSTEMtodisplaytheSystemGUIscreen.Thebottom
lineintheblueboxundertheCab1labeldisplaysthetransmitterflowrate.
TherecommendedflowratevarieswiththenumberofPAmodulesandislistedbelow.RefertotheHEpump
modulemanualsection3.11onpage32forinstructionsonsettinguptheinverter/controllerstoproducethe
desiredtransmitterflowrate.