Specifications
Maxiva ULX Series
November 11, 2013
2‐29
888‐2628‐300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
Figure 2-14 PS Faults Screen
STEP 7 CustomizethetransmitterSystemSetup.System>SystemService>System
SetupontheGUI.TheSystemSetupscreendisplaysthesettingsforSystemPwr
Out,CenterFrequency(visualcarrierforanalogsystems),ModulationType,AC
LineVolt(VAC),Numberofexciters,NumberofCabinetsandExternalRF
Switch.Touchthescreenateachfield
toenterthedatapertinenttothesetting.
TheSystemSetupscreenisshowninFigure3‐25onpage3‐22.
STEP 8 CustomizethecabinetSetup.PressSystem>SystemService>System
Setup>CabinetSetupontheGUI.Touchthescreenateachfieldtoenterthe
correctdataforCABPwrOut(W),NumberofPA’s,NumberofIPA’sandCooling
Pumps(numberpresent).TheCabinetSetupscreenisshownin
Figure3‐29on
page3‐26.
STEP 9 Endofprocedure.
2.15 CoolingSystemSetup
Followtheremainingstepstocompletethecoolingsystemsetup.
2.15.1 SettingtheTransmitterFlowRate
ThecoolantflowrateisdeterminedbytheHEpumpmoduleinverter/controllerfrequency.Ifothertypesofpump
moduleareusedtheflowrateiscontrolledbyadjustmentofthecabinetinletvalve.
TheflowratecanbecheckedviathetransmitterGUI.PressSYSTEMtodisplaytheSystemGUIscreen.Thebottom
lineintheblueboxundertheCab1labeldisplaysthetransmitterflowrate.
TherecommendedflowratevarieswiththenumberofPAmodulesandislistedbelow.RefertotheHEpump
modulemanualsection3.11onpage3‐2forinstructionsonsettinguptheinverter/controllerstoproducethe
desiredtransmitterflowrate.