Specifications

Maxiva ULX Series
November 11, 2013
23
8882628300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
Ambienttemperatureandrelativehumidityshouldalwaysrangebetweenthefollowinglimitsatthecabinet
installationlocation:
Ambienttemperature:0to+45
o
C.Derate2degreesCper300mAMSL.
Relativehumidity:0to95%noncondensing
Note
Failure to follow these installation instructions may void the warranty.
2.5 TransmitterCabinetPlacement
Thetransmittercabinetshouldbeplacedwhereitwillhaveapproximately1meterclearanceoneachsideandinthe
back.Thefrontofthetransmittershouldhaveaclearanceofatleast1.5meterstoallowaccessforremovaland
installationofthe PAmodules.Thereareseveraldrawingsincluded
inthedrawingpackagetohelpplanthecabinet
placement:
OutlineDrawing
RFEquipmentLayout
LiquidCoolingSystemLayout
STEP 1 Removetheboltsorstrapsholdingthetransmittertothewoodenpalletand
carefullyslidethecabinetoffthepallet.
STEP 2 Removereardoorandsetasideinasafeplacefortherestoftheinstallation
process.
MULTICABINETMODELS:
STEP 3 Placecabinetsinpositionandcarefullyalign.
ALLMODELS:
STEP 4 Uselevellingshimsundertransmittercabinetasrequiredtomakesurethe
transmitterislevelandsolid(notrocking).
STEP 5 InstallDripTray.Thealuminumdriptrayslidesunderthetransmitterjust
belowthereardoorpanel.Thedriptrayrestsonthefloorandiscentered
underneaththerearoftheMaxivatransmitter.Itshouldbechecked
periodicallyforpresenceofcoolant.
Note
Do not open the packaging for, or install IPA (driver), or PA modules at this time. These will be installed
just before the initial turn on.
2.6 RFSystemInstallation
RefertotheRFSystemLayoutdrawingandtoinstallationnotesin"2.3InstallationSequence"onpage22.
RefertotheRFLayoutandElectricalInstallationdrawingsforPatchPanelconnections.
Caution
ALWAYS SHUT THE TRANSMITTER OFF BEFORE REMOVING COAX
PATCHES TO PREVENT POSSIBLE DAMAGE TO THE ANCHOR INSULATORS
(BULLETS).