Specifications
Section-2 Installation
November 11, 2013
2‐2
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
SystemDrawingNotes:
1.)RFSystemLayout843‐5601‐288isforsystemscontaininguptofourmodules.843‐5601‐281isforsystems
containingsixtosixteenmodules.
2.)TheHarrisBroadcastHEpumpmoduleincludesadocumentationpackage(DP)988‐2625‐001.Thepumpmodule
DPincludestheHEpumpmoduletechnicalmanual888‐2625‐001,outlinedrawing843‐5607‐068,andlayout
drawing843‐5607‐072.
2.3 InstallationSequence
Stepsintheinstallationsectionsarenumbered.Aseachstepiscompleted,thestepnumbercanbecircledto
indicatecompletion.Thisprovidesaquickconfidencecheckattheendoftheprocedurethatnostepwasskipped.
Theprimarygoalofeachstepisindicatedbyboldletters,with
therestofthe paragraphbeingsupportinformation.
Note
In case of discrepancy between connections listed in schematics versus information given in this manual,
the wiring information in the schematics should be considered the most reliable. All connections listed in
this section should be verified with the schematics before initial turn on.
Whenperformingtheinstallation,afterthetransmittercabinet(s)areinplace,plantorunthetransmitteroutput
transmissionlinesfirst,thentheliquidcoolingsystemplumbinglines,andfinallytheelectricalconduitruns.Ifair
handlingductworkistobeinstalled,planalloftheRF,plumbingandconduitruns
toleaveroomfortheductwork.
Thereasonforthisinstallationorderisthatrigidcoaxrunsmustbeinstalledwithminimumelbows.IftheRFruns
encounterobstaclessuchasliquidcoolantlines,conduit,andductworkmoreelbowswillberequired.TheRFlines
shouldhaveaminimumnumberofelbowsforbestperformance.
Heavydutyhosecanbeusedinsteadofrigidcopperline,hoseiseasiertoinstallandcanbeinstalledlast,aslongas
largeradiusturnsareusedandsharpbendsofthehosesareavoided.Hosemustbesupportedmorefrequentlythan
rigidcopper.Goodsupportisrequiredto
avoidsagging,becauseitcantrapliquidwhenthesystemisdrained,stress
thehoseatthesupportpoints,andifthesag gingissevere,causeflowrestrictionduetohosecollapseatthe
supportpoints.Conduit(cable)traysofferthebestsupportforthecoolanthoseruns.943‐5601‐308
2.4 OperatingEnvironment
Theselectionofaproperinstallationlocationisessentialforequipmentlongevityandreliability.Donot installthe
transmitterinplaceswhereitmaybeexposedtomechanicalshocks,excessivevibration,dust,water,saltyair,or
acidicgas.
Table2‐1MaxivaULXSystemDrawings
SystemDrawings 1‐Cabinet 2‐Cabinet 3‐Cabinet
SchematicDocumentList 943‐5601‐511 943‐5601‐511 943‐5601‐511
CoverSheet 843‐5601‐511 843‐5601‐511 843‐5601‐511
OutlineDrawing 843‐5601‐279 843‐5601‐293 843‐5601‐302
BlockDiagram 843‐5601‐284 843‐5601‐299 843‐5601‐299
ACPowerFlow 843‐5601‐583 843‐5601‐297 843‐5601‐306
RFSystemLayout 843‐5601‐281 843‐5601‐295 843‐5601‐304
ExternalWiring 843‐5601‐705 843‐5601‐296 843‐5601‐305
WiringDiagramPAMain 843‐5601‐001 843‐5601‐001 843‐5601‐001
WiringDiagramAdditionalPACabinet N/A 843‐5601‐938 843‐5601‐938
Layout,TypicalPlumbing 843‐5607‐072 843‐5607‐07 2 843‐5607‐072