Specifications

Section-2 Installation
November 11, 2013
22
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
SystemDrawingNotes:
1.)RFSystemLayout8435601288isforsystemscontaininguptofourmodules.843‐5601281isforsystems
containingsixtosixteenmodules.
2.)TheHarrisBroadcastHEpumpmoduleincludesadocumentationpackage(DP)9882625001.Thepumpmodule
DPincludestheHEpumpmoduletechnicalmanual8882625001,outlinedrawing8435607068,andlayout
drawing8435607072.
2.3 InstallationSequence
Stepsintheinstallationsectionsarenumbered.Aseachstepiscompleted,thestepnumbercanbecircledto
indicatecompletion.Thisprovidesaquickconfidencecheckattheendoftheprocedurethatnostepwasskipped.
Theprimarygoalofeachstepisindicatedbyboldletters,with
therestofthe paragraphbeingsupportinformation.
Note
In case of discrepancy between connections listed in schematics versus information given in this manual,
the wiring information in the schematics should be considered the most reliable. All connections listed in
this section should be verified with the schematics before initial turn on.
Whenperformingtheinstallation,afterthetransmittercabinet(s)areinplace,plantorunthetransmitteroutput
transmissionlinesfirst,thentheliquidcoolingsystemplumbinglines,andfinallytheelectricalconduitruns.Ifair
handlingductworkistobeinstalled,planalloftheRF,plumbingandconduitruns
toleaveroomfortheductwork.
Thereasonforthisinstallationorderisthatrigidcoaxrunsmustbeinstalledwithminimumelbows.IftheRFruns
encounterobstaclessuchasliquidcoolantlines,conduit,andductworkmoreelbowswillberequired.TheRFlines
shouldhaveaminimumnumberofelbowsforbestperformance.
Heavydutyhosecanbeusedinsteadofrigidcopperline,hoseiseasiertoinstallandcanbeinstalledlast,aslongas
largeradiusturnsareusedandsharpbendsofthehosesareavoided.Hosemustbesupportedmorefrequentlythan
rigidcopper.Goodsupportisrequiredto
avoidsagging,becauseitcantrapliquidwhenthesystemisdrained,stress
thehoseatthesupportpoints,andifthesag gingissevere,causeflowrestrictionduetohosecollapseatthe
supportpoints.Conduit(cable)traysofferthebestsupportforthecoolanthoseruns.9435601308
2.4 OperatingEnvironment
Theselectionofaproperinstallationlocationisessentialforequipmentlongevityandreliability.Donot installthe
transmitterinplaceswhereitmaybeexposedtomechanicalshocks,excessivevibration,dust,water,saltyair,or
acidicgas.
Table21MaxivaULXSystemDrawings
SystemDrawings 1Cabinet 2Cabinet 3Cabinet
SchematicDocumentList 9435601511 9435601511 9435601511
CoverSheet 8435601511 8435601511 8435601511
OutlineDrawing 8435601279 8435601293 8435601302
BlockDiagram 8435601284 8435601299 8435601299
ACPowerFlow 8435601583 8435601297 8435601306
RFSystemLayout 8435601281 8435601295 8435601304
ExternalWiring 8435601705 8435601296 8435601305
WiringDiagramPAMain 8435601001 8435601001 8435601001
WiringDiagramAdditionalPACabinet N/A 8435601938 8435601938
Layout,TypicalPlumbing 8435607072 843560707 2 8435607072