Specifications
Section-1 Introduction
November 11, 2013
1‐12
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
1.2.9.1 CoolingSystemControlPanel
Thecoolingsystemcontrolpanelcontrolstheoperationofthepumpmodule/heatexchanger,andsendsfaultand
statusinformationtotheTCU.ThecoolingsystemcontrolcableconnectsthecontrolpaneltocustomerI/Opanelon
thetopofthetransmittercabinet.
Thepumpcontrolsignalsaredescribedintheexternalwiringdiagram843‐5601‐705,andintheHEpumpmodule
technicalmanual888‐2625‐001.
Figure 1-12 HE Cooling Control Panel
1.2.9.2 PumpModule/HeatExchanger
Thecontrolpanel/pumpmoduleandheatexchangerareseparatemodularunits.Thecontrolpanel/pumpmoduleis
self‐containedinonerackandincludesinvertercontrollers,anexpansiontank,airpurger/vent,pressuregauges,
pressurereliefvalve,strainer,anddualpumpsoperatinginmain/standbymode.Thecontrolpanel/pumpmoduleis
designedforindoor
operation(somepreviousmodelsweresuitableforoutdooruse).Thepumpmoduleandcontrol
panelshouldbelocatednearthetransmitterifpossible.Theheatexchangerassemblyisdesignedforoutdoor
mounting.