Figure a-3 Measurement for Cutback of Inner Conductor
a.3 Cutting The Transmission Line
Asquaresmoothcutisrequired.Severalmethods,listedbelow,maybeusedwiththechoicedependingontools
andlaboravailable.
1. Method1.Ahandhacksawandcastironcuttingguideareagoodcombinationformakinga
cutwithaminimumoftoolsforoneortwo pieces,butcanbeverylaborintensiveforputting
upanentiresystem.SeeFigurea‐4.
2. Method2.Handbandsaw:Thesepopularsawscanberentedorpurchased.SeeFigurea‐5.
3. Method3.Swingarmbandsaw:Thisisagoodwaytogoifonecanberentedorborrowed.
Manypipefittersandelectricalcontractorsownthem.Ifthesawhasanautomaticfeed,cut
slowly.Itiscriticalthatthesupportsawhorsesbemadelevelwiththesaw.
Testcutsshould
firstbemadeusingscrappipeorawood4x4toverifythatthebladeisnotcreepingandthe
sawisinalignment.SeeFigurea‐6.
Caution
DO NOT OVER TIGHTEN THE VISE USED WITH THESE SAWS. IT WILL BE
DIFFICULT TO PUT THE FLANGE ON AN OUT OF ROUND PIPE.
4. Method4.Tubingcutter:Thisisgenerallynotrecommended.Manycutsendupwith
crimpedendsduetodullcuttersortryingtocuttoofast.Usewithcaution.Avoidifpossible
unlesssomeoneisavailablethathashadalotofexperienceusingatubingcutteronthistype
of
installation.SeeFigurea‐7.
5. Method5.Cutoffsaw:Thesesawsaresimilartoradialarmsaws.Itisraretofindonebig
enoughtocut6‐1/8”line.Thesetupissimilartotheswingarmbandsaw.See
Figurea‐6.
Cutback
for inner
conductor.
The amount of cutback vary for different
transmission line manufacturers.