Specifications

Appendix-a Cutting & Soldering Transmission Line
November 11, 2013
a2
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
6. Measuretheflangefacetoflangefacedimensionaftersolderingtoconfirmtheproper
lengthandtodeterminetheinitiallengthoftheinnerconductor.
7. Determinethelengthoftheinnerconductorbyusingtheflangefacetoflangefacedimen
sionoftheouterconductorandsubtractingthedimensionoftheanchorconnector(bullet)
showninFigurea3.Thisdimensiondeterminesthepropercutbackoftheinnerconductor
forbothendsofthelineatthesametime.donotdoublethisdimensionwhensubtracting
fromtheouterconductorlength.
8. Cuttheinnerconductoranddeburthecutedges.
9. Ensuretheinsideoftheouterconductorisclean;theninserttheinnerconductor.Thelineis
readytoinstall.
Figure a-1 Measurements When Elbows Are Used
Figure a-2 Outer Conductor Measurements
See Section Below
Cut Length
Outer Conductor
Flange to Flange Length
Flange
Silver Solder Ring
(some suppliers may
not provide this grove)
Outer Conductor
Cut Back For Each Flange
Groove For
O-ring
Mating Surface
Teflon Portion
of Bullet
Note: The cutback will vary for different
transmission line manufacturers.