Specifications
Maxiva ULX Series
November 11, 2013
1‐9
888‐2628‐300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
hybrid,thesecondstageatwo‐way4.77dBhybrid,andthe3rdstageisatwo‐way6dBhybrid.Theuseof
rejectloadsinconjunctionwiththehybridsallowscontinuousoperationofthePAmoduleintheeventofa
PApalletfailure.Thecombinercontainsforwardandreflecteddirectional
couplersatitsoutput.Detector
circuitsdelivertheforwardandreflectedoutputsamplestothemonitorboard,whichindicatestheforward
powerlevelindBmandusesthereflectedsignalforVSWRmonitoringandfaultprotectionforthemodule.
AnotherdirectionalcouplerprovidesanattenuatedsampleofoutputRFsignal
toanoptionalcoaxialport
atthefrontofthePAmodule(i).
EachPAmoduleisaself‐containedtransmitterincludingthepowersupplywithitsowninternalcontrol,monitoring,
andprotection.ThemodulesreceivebasicOn/Off,Mute,&Restartcommandsfromthetransmittercontrolsystem.
ThismeansthateachmodulewillprotectitselfwithoutrelyingontheTCU.
1.2.6.1 ModuleControl
TheprimarymethodforcontrolandmonitoringofPAModulesistheindividualfiftyconductorribboncablebusthe
TCUPAInterfaceboard(s).ThesebussesarecalledDriveA(forpreampAandIPAA),DriveB(forpreampBandIPA
B),andBP1throughBP4(forPA
backplanes A5,A6,A8,andA9respectively).EachmodulecontainsaCPLDbased
monitorboardthatisresponsibleforreportingfaultsbacktotheTCUandfortakingactionwhentheON/STBY
commandisissuedbytheTCU.ThecabinetbusconnectstoeachPAand IPAmodulebackplane,it
containsthe
PA_voltage_selectline,whichsetstheDCoutputvoltageofeachoftheeightACtoDCconvertersintheIPAandPA
modules.Theoutputcanbeswitchedbetween44,46,48,or50VDC,dependingontheoperatingfrequency.
1.2.7 IPAModules(modified)
MaxivacabinetscontaintwopredrivermodulesandtwoIPAmodules.EachpredrivermoduleisdedicatedtoanIPA
moduleandtheyswitchasapair.TwotypesofULXIPAmodulesareused.
PAcabinetsthatusemorethaneightPAmodulesusestandardPAmodulesintheIPAslots.TheseIPAmodulescan
beswappedwithanyPAmoduleinthecabinet.
PAcabinetsthatuseeightPAmodulesorlessusemodifiedIPAmodules.ThesemodifiedIPAmodulescanbeused
onlyasIPAmodulesandcannotbeinstalledinPAmoduleslots.partnumbersforthemodifiedIPA modulesare971‐
0040‐011(noRFsampleport)or971‐0040‐006
(withRFsampleport)
Figure 1-8 IPA Module Simplified Block Diagram