Specifications
Section-6 Diagnostics
November 11, 2013
6‐6
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
Table6‐5SystemFaultsList
TYPE Description
FaultLevelor
Threshold
TransmitterAction ThreeStrike
Availablein
LifeSupport
AirTemp Ambientcontrolenclosure
airtemperaturehas
exceeded65°C.Thesourceof
thistempcanbefromthe
tempsensorintheMCM
moduleforinstance.
65°C WARNING NO YES
CoolantFlow Coolantflowislessthanthe
minimumLitersperminute
flowrateforthenumberof
PAspresent
Dependson
transmittermodel
RFMUTEfollowedbypump
switchover.Ifstillinsufficientflow
RFMUTEstaysactiveuntilproper
flowisrestored.Transmitter
returnstoONstateautomatically
whenfaultclears.
NO YES
CoolantLeak Coolantleakdetectedinside
transmittercabinet
N/A TransmitterFaultOFF.Amanual
turnONisrequiredforrecovery
NO YES
CoolantInlet
Temperature
Coolanttemperaturehas
exceeded55°C
Warningat55°C,
Faultat65°C
WARNING.RFMUTEifcoolant
temperaturereaches65°C.
TransmitterreturnstoONstate
automaticallywhenfaultclears.
NO YES
CoolantOutlet
Temperature
Coolanttemperaturehas
exceeded55°C
Warningat55°C,
Faultat68°C
WARNING.RFMUTEifcoolant
temperaturereaches68°C.
TransmitterreturnstoONstate
automaticallywhenfaultclears.
NO YES
CoolantFault Thetankinthepumpmodule
isempty
Opencircuitfrom
leveldetector
insidetank
TransmitterFaultOFF.Amanual
turnONisrequiredforrecovery
NO YES
CoolantWarning Thecoolantinthetankislow Opencircuitfrom
leveldetector
insidetank
WARNING NO YES
Fan1Fault FanACcurrenttoolowortoo
high
FaultlevelsLOW:
100mA,HIGH:800
mA
WARNING NO YES
Fan2Fault WARNING NO YES
SystemSafety
Interlock
Opencircuit TransmitterFaultOFF.Amanual
turnONisrequiredforrecovery
NO YES
SystemRFMute
Interlock
Opencircuit TransmitterRFMUTE.
TransmitterreturnstoONstate
automaticallywhentheinterlock
isclosed.
NO YES
CabinetSafety
Interlock
Opencircuit CabinetFaultOFF.Amanualturn
ONisrequiredforrecovery
NO YES
CabinetRFMute
Interlock
Opencircuit CabinetRFMUTE.Cabinetreturns
toONstateautomaticallywhen
theinterlockisclosed.
NO YES