Specifications
Section-1 Introduction
November 11, 2013
1‐6
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
1.2.4.1 GraphicalUserInterface
TheTCUfrontpanel(in PAcabinetoneonmulti‐cabinettransmitters)containsthegraphicaluserinterfacewhichis
a5.25",color,1/4VGA,LCD,touchscreen,panelPC,display.Thetouchscreendisplayusessoftwarebuttonsto
monitorandcontrolthetransmitter.Aseriesoffrontpanelpushbuttonsprovideimmediateaccess
tothemost
importantcommandsandstatusinformation.
TCU’ sinadditionalPAcabinetswillnotbeequippedwithGUIscreens.
Figure 1-4 TCU Front Control Panel
1.2.5 ControlSystemCommunications
ThecontrolsystemusesaserialcommunicationssystemcalledaCANbus.CANstandsforControllerAreaNetwork.
TheCANbusisaclosedloopserialnetworkcontrolledbythemainTCU.TheCANbusconnectsthemainTCUwith
TCU’ sinothercabinets.EachTCUboardconnectedtotheCAN
busisconsideredanodeandthereforehasaspecific
address.ThisallowsthemasterTCUtousethesystembustogatherinformationfromallpartsofthetransmitter
anddisplayitontheGUI.OnebigadvantageoftheCANbusisthatitrequiresonly2wires
ofthesystemcontrolbus
ribboncable,eliminatingalargeamountofdiscretewiringwhich wouldotherwiseberequired.
ThesystembustiesTCU’ sineachcabinetto gether.Thecabinetbusisforthemostpartaduplicateofthesystembus
butintendedtoconnectnodeswithineachindividualcabinet.ThecabinetbusoriginatesintheMCMmodule within
eachTCU.The cabinetbusisdesignedtokeepthe
PAcabinetsoperatingevenifthecommunicationswiththe
mastercabinetTCUislost.
1.2.5.1 SoftwareUpdates
Softwaredoesnotneedtobeloadedintothetransmitterunlessnewcomponentsareinstalledoranupdateis
directedfromHarrisBroadcast.M2XexciterandTCUPCM(processorcontrolmodule)&MCM(maincontroller
module)softwarecanbeupdatedviaremotewebbrowserconnectiontoanexternalcomputer.Thetransmitter,
as
shippedfromthefactory ,ispreloadedandreadytorun.
1.2.5.2 RemoteControl
TheULXtransmitterhasthebasicdiscretewiredparallelremotecontrolwiththestandardconnectionsforcontrol,
statusandanalogmonitoringlocatedonthecustomerI/Opanelonthetopofcabinet1.Seesection
2.18for
additionalparallelremotecontroldetails.
MaxivatransmittersincludeawebenabledremoteGUIinterfacethatprovidescomprehensiveremotecontroland
monitoringofdatapointswithinthetransmitter.ItincludesanSNMP(simplenetworkmanagementprotocol)
managerwhichallowsintegrationwithmostcontrolsystemsviatheInternetorLAN.Theremotewebconnectionis
madeviaan
EthernetportonthecustomerI/Opanelonthetopofcabinetone.
1.2.6 PAModule
ULXPAmodulesutilizeLDMOS(laterallydiffusedmetaloxidesemi‐conductor)ampl ifierstoproduceupto1880W
analogpeak,800WaverageATSC,or650WaverageCOFDMpoweroutput(theseareapproximatevaluesandvary