Specifications

Section-5 Maintenance
November 11, 2013
538
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 8882628300
5.13.10 LeakDetectorandCabinetDrains
Aleakdetectorisinstalledatthebottomofthecabinet.TheleakdetectorisshowninFigure51onpage538.Itis
mountedinthebottomc abinetnearthecenter.Theleakdetectorconsistsofasmallreservoirwithafloat.TheTCU
monitorsthisleakdetectortoalertthesystemshouldaleakoccur.Aleakdetectionwillcausethetransmitterand
thepumptobeshutoffbyactivatingthepump
interlocksignal.Inordertoresettheleakdetectorthefloat
assemblymustberemovedandadrainplugremoved.Removingthedrainplugallowsthereservoirtodrainintothe
drippanatthebottomofthecabinet.Oncethereservoirisdrainedandtheleakdetectorassemblyreinstalled
the
transmittercanberestartedbypressingtheONbuttononthefrontoftheTCU.
Thecabinetcanbeemptiedofcoolantbyfirstturningoffthepumps,closingtheinletandoutletvalvesatthetopof
thetransmitterandthenopeningthefitt ingsattheendofthesupplyandreturnsidedrainhosesinsidethecabinet.
Usea7/16"openendwrenchto
openthedrainvalves.
Figure 5-1 Leak Detector and Cabinet Drains
5.14 TCUMaintenance
5.14.1 TCUMCMandPCM2SoftwareUploads
TCUMCMandPCM2softwareuploadsarecoveredinSection3.9.3.4,SoftwareManagement,onpage331.
5.14.2 PanelPCTouchScreenContrast
ThepanelPCGUIscreencontrastisnotadjustable.
Leak
Detector
ReturnSide
DrainHose
SupplySide
DrainHose