Specifications
Section-5 Maintenance
November 11, 2013
5‐22
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
Figure 5-13 System Coupler
5.10.1.1 CalibrateForwardTotalPower
STEP 1 Calibratetheaveragingpowermeterfollowingmanufacturersinstructions.
STEP 2 Setthemeteroffsettothevalueprintedonthecoupler,orassuppliedwithadata
sheetincludedwiththefactorytestdata.
STEP 3 Removethesamplecablefromthesystemforwarddirectionalcoupler(afterfilter)to
becalibrated(seeFigure5‐13).
STEP 4 Connectthepowermeterprobetothesystemforwarddirectionalcouplerport.
Couplerdesignsliketheoneshownin
Figure5‐13musthave50ohmterminationson
theportoppositethemeasurementport.Thepowermeterprobemustbesupported
topreventdamagetoconnectors.
STEP 5 PressandholdthepowerLOWERbuttonfor40secondsornavigatetoOutputscreen
andsetCab.Ref .Pwr.tozero.Eitherofthesestepswi llinsurethatthetransmitter
doesnotproducelargeamountsofRFpoweratturnon.
STEP 6 Turnontransmitterandwhilemonitoringcabinetreflectedpower,slowlyadjustthe
Maxivadigitaltransmitteroutputuptolicensednominalpower(asprogrammedin
theSystemSetupscreen).Ifhighlevelsofcabinetreflectedpowerarenoted,stop
raisingpower,abadload,transmissionlineconnection,orantennaisindicated.
STEP 7 Allowthetransmittertorunforseveralminutesatnominalpowertogivethe
amplifierstimetowarmupandstabilize.
STEP 8 PressthemanualbuttonontheTCUandholditinfor5seconds.
STEP 9 Re‐adjustthetransmitterpoweroutputasrequiredtoreachlicensednominalpower.
Besureitisstable.
STEP 10 Disconnectthepowermeterprobefromtheforwardcouplerportthenreconnect
forwardsamplecable.
Note
The detector voltage values are provided on the Sys Pwr Calibrate screen shown in Figure 5-14. They are
listed in the column to the right labelled Detector. The Sys Fwd (kW) detector voltage level should be
between 3.0 and 3.2V at full rated power. Operating in this range insures accuracy (detector’s linear
region). If the detected levels are too high, attenuation must be added at the coupler port to reduce the
detected voltage level.
STEP 11 AccesstheCalibrationscreenbynavigatingtoSystem>SystemService>System
Setup>SystemPowerCalibrateasshownin
Figure5‐14.
Coupler
Reflected
Forward
Coupler