Specifications
Section-5 Maintenance
November 11, 2013
5‐18
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
5.9.3.1 CalibrateSystemReflectedPower
Note
Before attempting reflected calibration forward (visual and aural) calibration must be confirmed.
STEP 1 Turnonandadjusttransmitterto100%ratedvisualpeakpowerasmeasuredwithan
averagingpowermeter.
STEP 2 .Setvideoinputsignalto50%flatfield(gray)andturnsoundcarrieron.
STEP 3 PressSystem>SystemService>SystemSetup>SystemCalibratetoviewtheGUIscreen
showninFigure5‐9onpage5‐15.
STEP 4 PressdisableVSWR.ThisdisablesVSWRprotectionfor5minutes.Ifreflected
calibrationisnotfinishedwithin5minutesthetransmitterwillfaultoffandwillneedto
berestartedbeforerepeatingthereflectedcalibration.Navigatingawayfromthe
calibrationscreenwillalsoreactivateVSWRprotection.
STEP 5 Removethesamplecablefromthesystemreflecteddirectionalcoupler(seeFigure5‐
8,above).Ifthereareattenuatorsonthereflectedcouplerportkeepthemwiththe
reflectedsamplecable.
STEP 6 Attacha10dBattenuatortothereflectedsamplecable(alongwithexisting
attenuators).
STEP 7 Removethe50ohmterminatorfromtheoppositecouplerportandplaceitonthe
reflectedport.
STEP 8 Placethereflectedcable(with10dBpadontheportwheretheterminatorwas
removed.Thisessentiallyattachesthereflectedcable(with10dBpad)toaforward
sample.
Note
The detector level (at licensed output power) should be between 2-3 V when the reflected cable is attached
to a forward port with a 10 dB pad. If the reflected detector voltage is too high, additional pads must be
added to get the voltage in the 2-3 V range. The added pads will stay with the reflected cable when it is
moved back to the reflected port later in the procedure. The 10 dB pad will be removed when the reflected
cable is placed back on the reflected port.
STEP 9 ClickonthecorrespondingwindowforSysRefldpower,openingan umericentrybox.
STEP 10 Enterthevaluethatis10%oflicensednominaloutputpower.
STEP 11 ClickonDONEtostorethechanges,orCANCELtoignoreallchangesmade.Record
thereflecteddetectorvoltageforlateruseinsettingthereflectedpowerthreshold.
Note
Refer to "3.9.3.1.2 System Thresholds" on page 3-24 to get information on setting the system reflected
threshold level. This level must be set before testing the VSWR protection (reflected power trip point). The
reflected trip level should be set to the voltage level recorded in the previous step minus 100 mV.
STEP 12 VerifytheVSWRprotectionbypressingtheEnableVSWRbuttonontheCALIBRATE
screen.Thetransmittershouldfaultoff.
STEP 13 Removetheterminatorfromthereflectedportandplaceitontheforwardport.
STEP 14 Removethe10dBattenuatorfromthereflectedcable.
STEP 15 Returnthereflectedcabletothereflectedport.
STEP 16 Turnonthetransmitter.Itshouldcomeuptolicensednominaloutputpower.
STEP 17 Endofprocedure.
5.9.3.2 CalibrateCabinetReflectedPower
Cabinetreflectedpowerisnormallycalibratedatthefactoryduringfinaltestanditmaynotneedtobecalibratedin
thefield.ThecabinetreflectedtrippointhasbeensetatthefactoryandisnotaccessibleviatheGUI.Should
recalibrationofcabinetreflectedpowerberequired,anddetector
voltagesaresignificantlychangedforsome
reason,thecabinetreflectedtriplevelcanonlybeadjustedthroughuseofaterminalemulatorprogramlike
Terater m.ContactHarrisserviceifthisisneeded.