Specifications

Maxiva ULX Series
November 11, 2013
515
8882628300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
STEP 9 Allowthetransmittertorunforseveralminutestogivetheamplifierstimetowarm
upandstabilize.
STEP 10 Verifythatthesyncratioiscorrectforthedesiredoperatingsystem.Thesynclevelis
setintheM2Xexciter.TypicalsynclevelforPALis300mVand40IREunitsforNTSC.
Readjustoutputpowerifsync.levelis readjusted.
STEP 11 PressthemanualbuttonontheTCUandholditinfor5seconds.
STEP 12 Verifythattheoutputpowerisstableandatthedesiredpeakvisualoutputpower
level(dividethisaveragepowerreading,fromthepowermeter,byoneofthefactors
in
Section5.9.1onpage512,toobtainpeakvalueofthevisioncarrier).
STEP 13 Disconnectthepowermeterprobefromtheforwardcouplerport,thenreconnect
forwardsamplecabletocoupler.
Note
The detector voltage values are provided on the Sys Pwr Calibrate screen shown in Figure 5-9. They are
in the column to the right labelled Detector. The Sys Vis (kW) detector voltage level should be between 3.0
and 3.2V at full rated power. Operating in this range insures measurement accuracy (detectors linear
region). If the detected levels are too high, attenuation must be added at the coupler port to reduce the
detected voltage level.
STEP 14 AccesstheSysPwrCalibratescreenpressSystem>SystemService>System
Setup>SystemPowerCalibrateshowninFigure59.
Figure 5-9 System Setup and System Power Meter Calibration Screens (Analog)
STEP 15 ClickonthecorrespondingwindowforSysVispower,openinganumericentrybox.
STEP 16 Enterthevalue(inpeakkW)determinedinstepSTEP12onpage515above.
STEP 17 ClickonDONEtostorethechanges,orCANCELtoignoreallchangesmade.
STEP 18 PresstheAutoPowerControlbuttontoenableALC.
STEP 19 Enablethesound(aural)carrierviatheApexM2Xcontrolscreens.
STEP 20 Restorenormalvideoprograminputsignal.
STEP 21 Endofprocedure.
5.9.2.2 CalibrateCabinetForwardVisualPower
STEP 1 BeforeperformingcabinetcalibrationconfirmthatthecabinetALCvoltageiswithin
therangedescribedin
Section5.8.1onpage511.
STEP 2 Repeatthepreviousprocedureusingtheinternalcabinetforward(incident)coupler
sample,shownin
Figure511onpage516,enteringthedatainthecorrespondingPA
cabinetcalibratewindowshowninFigure510.Thisscreenisaccessedbypressing
System>SystemService>CabinetSetup>CabinetPowerCalibrate.