Specifications
Maxiva ULX Series
November 11, 2013
5‐13
888‐2628‐300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
5.9.1.1 AverageandPeakConversionFormulaandExamples
AveragePower=PeakVisualPower*Factor
PeakVisualPower=AveragePower/Factor
Example1:CalculatetheaveragepowerofaSystemMtransmitteroperatingat1000Wpeakvisualwith
anauralinjectionlevelof‐10dB.
FactorforSystemMwith‐10dBauralinjection=0.695
AveragePower=1000W*0.695=695W
Example2:CalculatethepeakvisualpowerofaSystemKtransmitterwith‐13dBauralinjectionifthe
averagepoweris1600W.
FactorforSystemKwith‐13dBauralinjection=0.645
PeakVisualPower=1600W/0.645=2480W
Example3:CalculatetheaveragepowerofaSystemBtransmitteroperatingat60kWpeakvisualwithno
aural.
FactorofSystemB,visualonly=0.567
AveragePower=60kW*0.567=34.02kW
Usethefollowingformulatocalculatefactorsforotherauralinjectionlevels:
Factor=v+10
(a/10)
Where:v=visualonlyfactorforsystem
a=auralinjectionlevel
*Incaseswithmultipleauralcarriers,(Nicam,DualCarrier)addthefactorsforeachauralcarriertothe
visualfactor.
Example4:Auralcarriersat‐13dBand‐20dBforsystemB
Factor= v+10(a/10)+10(a/10 )
Factor= v+10(‐13/10)+10(‐20/10)
Factor= 0.567+0.0501+0.01
Factor=0.627
5.9.2 ForwardPowerCali bration
EquipmentUsed:
• Maxivaprecisiondirectionalcouplers(precisionmeaningthatthecouplingratiohasbeen
measuredattheoperatingfrequency)
• Averagingpowermeterwithpowerprobe
Note
Power calibrations must be performed using the local GUI screen. In order to change calibration settings
the user must supply a login and a password. When the transmitter ships from the factory the local GUI
default login is "admin" and the default password is "admin" (do not include quotation marks in login or
password). The default password allows setting of remote passwords only. Refer to
"3.2.2 TCU - Initial
Login & Passwords" on page 3-2. You will not be able to make changes or have remote access without
changing the default username/password.