Specifications
Maxiva ULX Series
November 11, 2013
5‐7
888‐2628‐300 WARNING:Disconnectprimarypowerpriortoservicing.
Copyright©2013,HarrisBroadcast
5.4 PAModulePhasing
PhasingofthePAmodule sistightl ycontrolledatthefactory .Nopha singofthemodule s isrequir e dinthefield.PA
modulesandIPA(drivermodules,usedintransmitte rc abine tswith10to16PAmodule s)canbeuse dinanylocation
withoutre‐pha sing.Modified IPAmodule s,usedin
PAcabinet swith8orfewerPAmodules ,donotrequirephasing
eitherbutcanonlybeusedinIPAmoduleslots.
Note
Phasing between cabinets is required to minimize cabinet combiner reject power and it is accomplished
via the GUI screen. Cabinet phase and gain is controlled by adjusting the relative phase and RF output
levels of each cabinet using the preamplifiers. See
Section 3.7.2 on page 3-18 and Figure 3-18 on page 3-
18 to view adjustment screen.
5.5 PA&IPAModuleComponentID
BeforeattemptingPAorIPAmodulerepairsinthefielditisimportanttoproperlyidentifythefaultycomponents.
Figure 5-4 PA/IPA Module Pallet and Power Supply Numbering
Figure5‐4givesthepowersupplyandpalletidentificationnumbersforPAandunmodifiedIPAmodules.
ComponentsthatareremovedfrommodifiedIPAmodulesaredenotedwithasterisks.ModifiedIPAmodulesare
usedintransmitterswitheightorlessPAmodules.
ThetestconnectoronthefrontofthePAorIPAmodulecanbeusedtodeterminewhichpalletorpowersupplyhas
failed.Anoptionalhandheldmetercanbeattachedtotheconnectortodisplaythestatusandfaultinformation
outlinedin
Table5‐2.Iftheoptionalmeterisnotavailableamultimetercanbeusedtomeasurevoltagesonthe
connectorpins.Thenormalmeasuredvoltagesaregiveninthefollowingtableinparenthesis.Thesevoltagevalues
assumethatthemoduleisenabledbutnoRFinputisapplied.










