Specifications
Section-5 Maintenance
November 11, 2013
5‐6
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
Note
The system was drained to avoid leaking at this connection when the clamp is loosened. Loosening the
clamp allows the upper and lower manifolds to move relative to each other.
STEP 6 Usingthetopandbottommodulesineachhalfasalignmentfixtures , placea0.02"‐
0.03"thickshimonthecabinetPAshelfguidesforatopandbottommodule.
Carefullyinsertthetopandbottommodules(inthesectionbeingaligned)andinsure
shimiscapturedbetweenthe
modulecoldplate(bottom)edgenotchandthe
cabinetshelf
Note
The shims position the module slightly higher than normal. This insures that after alignment the module
can slide up slightly and onto the manifold connector. This is done to insure that the manifold connectors
are a little higher than the module connectors.
STEP 7 Insertthemoduleslowlyandcarefullyuntilfullyinsertedontothemanifold
connectors.
Note
The manifold may have to be moved slightly to allow proper alignment between module connectors and
manifold connectors. Do not aggressively insert or damage to the connectors may result.
STEP 8 Oncethetwomodulesarefullyinserted(andshimsareinplace)andseatedonthe
RFconnector,twofluidconnectors,AC/controlconnectorandalignmentpinthen
tightenthemanifoldbolts.
STEP 9 Repeatprocedureonothermanifoldasapplicable.
STEP 10 Tightenallhoseclampsandhardwareloosenedinprevioussteps.
STEP 11 Removealignmentmodulesandshims.
STEP 12 InstallallPAandIPAmodules.
STEP 13 Rechargesystemwithcoolant.
STEP 14 TurnonACpowerandrestoretransmittertonormaloperation.
STEP 15 Endofprocedure.
5.3 PAModule Bias
Re‐biasofthePAmodulesisnotrequiredontheMaxivaULXseriestransmitters.
AlignmentShims