Specifications
Section-5 Maintenance
November 11, 2013
5‐4
Copyright©2013,HarrisBroadcast
WARNING:Disconnectprimarypowerpriortoservicing. 888‐2628‐300
STEP 4 Wait30secondsformoduletocool.
STEP 5 Useascrewdriver(Phillips)toloosenandremovethescrewsthatholdthemodulein
therack.Thereisonescrewoneachsideofthemodule.
STEP 6 Pullthemodulehalfwayoutoftherack,thenrepositionhandstothesidesofthe
moduletobettersupporttheweight(22kg).Removethemodulefromtherack.
STEP 7 Endofprocedure.
Caution
DO NOT LET THE MODULE SWING DOWN WHEN PULLING THE MODULE
OUT OF THE RACK. THIS COULD CAUSE SEVERE DAMAGE TO THE
CONNECTORS ON THE BACK OF THE MODULE.
5.2.3 PAModuleInstallation
STEP 1 Inspecttheconnectorsontherearofthemoduletobesurethereisnodamageto
theliquidconnectorsortotheelectricalconnectors.
STEP 2 Inspecttheconnectorsinsidetheracktoconfirmthereisnoblockageandnodamage
totheliquidorelectricalconnectors.
STEP 3 ChecktobesurethatthePAmodulecircuitbreakerhasbeenturnedoff.
STEP 4 SlidethePAmodulegentlyintotherackuntilcontactismadewiththemating
connectors.
STEP 5 Pushevenlyonthefrontoffrontofthemodulewithaslightsidetosidemotionto
helpalignthematingconnectors.
STEP 6 Usefirm,moderatepressuretofullyseatthemodule.
Ifthemodulefailstoseatwithmoderatepressuredonotforcethemoduleintotherack.Removethemoduleand
inspectforinterference.
Note
In some cases it has been noted that it can be difficult to reinsert a hot PA module. If the connection is dif-
ficult (module doesn’t seat fully with moderate pressure) simply allow the module to cool sufficiently
before reinserting.
CheckthecoolantconnectorsonthebackofthePAmoduleand onthecoolantmanifold.Themanifoldconnector
hasanO‐ringseal(Figure5‐2)whichmustbeingoodconditiontopreventleaks.Ifthereisevidenceofamechanical
interferenceormisalignmentofthecoolantconnectorsonallthemodulesthenarackre‐alignmentmaybe
required.Thismayalsoberequiredifamanifoldisreplaced.Therackrealignmenthelpsalignthecoolant
connectorsinthemanifoldwiththecoolantconnectorsonthePAmodules.Ifrackalignment
isneededreferto5.2.5
onpage5‐5.
Figure 5-2 Manifold Coolant Connector O-ring
STEP 7 Installtheholddownscrewsandhandtighten.
STEP 8 Turnonthemodulecircuitbreaker.
STEP 9 PressthetransmitterONbuttontoreactivateallmodulesthatareoff.
STEP 10 Endofprocedure.
O-ring