Instruction Manual
Aphex Remote Pre Parametric MIDI Commands
Command Control Value Range
00h Input Gain 1Ah to 41h (26 to 65)
01h Main Max Out 00h to 1Bh (0 to 27)
02h Aux Max Out 00h to 1Bh (0 to 27)
03h Phantom Power 00h = OFF, 01h = ON
04h Low Cut Filter 00h = OFF, 01h = ON
05h Limiter (MicLim) 00h = OFF, 01h = ON
06h Polarity Reverse 00h = OFF, 01h = ON
07h Mute 00h = OFF, 01h = ON
08h Pad 00h = OFF, 01h = ON
0Ah Test Tone -20dB 00h = OFF, 01h = ON
0Bh Test Tone 0dB 00h = OFF, 01h = ON
17h Test Tone (alternative method) 00h = OFF, 01h = -20dB, 02h = 0dB
20h Request Parameter SysEx Dump 01h (required)
56h Request Extended SysEx Dump 00h (any value placeholder byte)
F0 00 00 38 xx xx xx xx xx
F7
SysEx Start
MIDI Channel
MIDI Device
xx
Net Number
Command
Mic Channel
Va
l
ue
xx xx xx
Command
Mic Channel
Va
l
ue
xx xx xx
Command
Mic Channel
Value
SysEx End
Put 1 to 64 3-byte Commands Here
Aphex MIDI I.D.
System Exclusive (SysEx) Parametric Control String
The Model 5200, will allow you to control your
Aphex 1788A or 188 from any MIDI controller. You
will need to be familiar be with the programming of
your MIDI device.