user manual Instruction Manual
DCR-1006A Ultrasonic Controller Rev. A1, 2/14
8
Automaon Products Group, Inc.
APG...Providing tailored soluons for measurement applicaons
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Stand Pipe Mounng
Stand pipes are used to provide headroom at
the top of a tank when the target is expected
to come closer to the sensor than the
minimum blanking distance. It’s very crical
that the stand pipe be installed perpendicular
to the target. This is especially important
on longer range applicaons. The pipe must
have smooth walls (no joints) and no burs or
obstrucons. If possible, cut the end of the
pipe at a 10°-45° angle (see drawing). Use
the largest diameter pipe and shortest length
possible. As a general rule, the diameter of
the pipe should be 1/2 the length. The pipe
ID must remain the same through it’s enre
length.
Slling Pipe Mounng
Slling pipes provide access to dicult areas
and help eliminate problems with foam.
The pipe must have smooth walls (no burs
or joints). Because the sound waves will
concentrate and propagate down the inside
walls of the tube, any irregularies on the
tube walls may produce echo returns and
cause false readings. Slling pipes are limited
to liquid targets that will not leave heavy
deposits on the tube walls. Because the
sound waves are conned inside the pipe,
it is usually necessary to greatly reduce the
sensors sensivity and pulses sengs. A vent
hole must be provided at the top of the pipe.
Be sure to keep the vent hole inside of the
blanking area.
Cut at angle
when possible
Vent Hole