• Specicaons
Sensor Operang Ranges:
DST or MNU 5000 series: 4 to 72 in. (101 to 1829 mm)
DST or MNU 7000 series: 6 to 144 in. (150 to 3658 mm)
DST or MNU 2000 series: 1 to 25 . (305 to 7620 mm)
DST or MNU 3000 series: 1.5 to 40 . (458 to 12192 mm)
Operang Voltage: 85-264 VAC or 12-24 VDC
4-20mA Vs: 9 to 28 VDC
Housing: PBT/Polycarbonate blend
Dimensions (in.): 6.25 x 3.125 x 2.25
Environmental Rang: NEMA 6P
Sample Rate: 100 to 1000 mS (programmable)
Resoluon: 0.1 in. (2.5 mm)
Accuracy: +/- 0.25% of detected range (with no temperature gradient)
Sensor Adjustments: via push buons or RS-485 interface to the APG Modbus
Soware or RST-5002 module.
Operang Temperature: -30 to 140
0
F (-34 to 60
0
C)
Sensor Beam Paern: 9
0
o-axis (maximum)
• Inspecon and Maintenance
The DCR-1006A requires lile maintenance but should be inspecon
periodically to ensure proper working order. Keep the sensor clean from heavy
buildup on the sensing face. Ensure that the wire connecons are secure,
sealed against the elements and free from corrosion.