user manual Instruction Manual

Rev. A1, 2/14 DCR-1006A Ultrasonic Controller
37
Automaon Products Group, Inc.
APG...Providing tailored soluons for measurement applicaons
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • sales@apgsensors.com
Specicaons
Sensor Operang Ranges:
DST or MNU 5000 series: 4 to 72 in. (101 to 1829 mm)
DST or MNU 7000 series: 6 to 144 in. (150 to 3658 mm)
DST or MNU 2000 series: 1 to 25 . (305 to 7620 mm)
DST or MNU 3000 series: 1.5 to 40 . (458 to 12192 mm)
Operang Voltage: 85-264 VAC or 12-24 VDC
4-20mA Vs: 9 to 28 VDC
Housing: PBT/Polycarbonate blend
Dimensions (in.): 6.25 x 3.125 x 2.25
Environmental Rang: NEMA 6P
Sample Rate: 100 to 1000 mS (programmable)
Resoluon: 0.1 in. (2.5 mm)
Accuracy: +/- 0.25% of detected range (with no temperature gradient)
Sensor Adjustments: via push buons or RS-485 interface to the APG Modbus
Soware or RST-5002 module.
Operang Temperature: -30 to 140
0
F (-34 to 60
0
C)
Sensor Beam Paern: 9
0
o-axis (maximum)
Inspecon and Maintenance
The DCR-1006A requires lile maintenance but should be inspecon
periodically to ensure proper working order. Keep the sensor clean from heavy
buildup on the sensing face. Ensure that the wire connecons are secure,
sealed against the elements and free from corrosion.