Owner's manual
B. Switch Settings
Banks A and B define the ASCII character(s) that the cash drawer will recognize as its opening sequence. Refer to
Chart
#1
for the proper switch settings for a particular ASCII character. Refer to the software supplier to determine the ASCII
sequence used as the cash drawer opening code. If one ASCII character is sent by the software package to open the cash
drawer, then only switch bank A must be set to match this character. Bank B settings will be ignored in one character
mode. If two characters are sent by the software package to open the cash drawer, then Bank A is the first character, and
Bank B is the second character.
Bank C interprets the COM port parameters of the signal. Bank C switch settings are defined as follows:
1 2 3 Baud Rate
OFFonon300
on OFF on 600
OFF OFF on 1200
on on OFF 2400
OFF on OFF 4800
on OFF OFF 9600
OFF OFF OFF 19,200
4 5 Parity
OFF on None
on OFF Even
OFF OFF Odd
6 Data Bits
on 7
OFF 8
7 Opening Characters
on 1
OFF 2
8_ Host Device
on DCE (Computer)
OFF DTE (Terminal)
*
The APG default settings are shown as
bold text
above.
Figure 6
Bank A
Bank B
Bank C